Chauvin Arnoux CA6550 10Kv Insulation Tester Megohmmeter

  • 1 Year Chauvin Arnoux Warranty
  • Stores up to 80,000 results
  • Tests insulation and conducts voltage
  • DataView software included

£2,898.50 exc VAT / £3,478.20 inc VAT

Description

Chauvin Arnoux CA6550 10Kv Insulation tester

1 Year Chauvin Arnoux Warranty


Chauvin Arnoux CA6550 Product Details:

The Chauvin Arnoux C.A 6550 megohmmeter is a high-end portable measuring instruments intended for the measurement of very high electrical insulation and resistance values, mounted in a rugged site housing with a cover; it has a graphic screen and can operate on battery or mains power.

With its site-proof casing, the Chauvin C.A 6550 insulation tester is used to check equipment insulation during manufacturing, on-site installation work, periodic inspections and recommissioning of installations.

Specially adapted for checking insulation on rotating machinery with a 12 kV power supply or higher, the Chauvin C.A6550 complies with the IEEE43 standard which recommends insulation testing at 5-10kV.

  • Fixed Test Voltage: 500V, 1,000V, 2,500V, 5,000V & 10,000V.
  • Variable Test Voltage: 40V – 10,000V – 3 presettable voltage values.
  • Ramp mode: 3 presettable ramps: start voltage / end voltage / duration.
  • Discharge after test: Automatic.
  • Timer: Up to 99 minutes 59 seconds.
  • Automatic calculation: DAR / PI / DD /ppm/V ratios.
  • Measurement display: 3 filters with 3 possible time-constant.
  • Programmable alarms: An alarm threshold can be memorised.
  • Storage: 256 recordings, 80,000 points: R, U, I and date.
  • Communication: Optically-isolated port for USB and RS232 links.
  • PC software: DataView.
  • Power supply: NiMH rechargeable batteries.
  • Battery charging: Battery charging possible while performing insulation measurements.
  • Electrical safety: 1,000V CAT IV – IEC 61010-1 and IEC 61557.
  • Dimensions: 340 x 300 x 200 mm.
  • Weight: 6.2 kg approx. (excluding accessories).
  • Chauvin Arnoux C.A 6550 Warranty: 1 year.

Full List of Products Included

  1. Chauvin Arnoux CA6550 Digital Megohmmeter
  2. Carrying Bag
  3. 2 x 3m Safety Leads with HV Plugs (Red/Blue)
  4. 3m Guard Test Leads with HV Plug and Rear Connector (Black
  5. 3 x Crocodile Clips (Red, Blue and Black)
  6. 2 x CAT IV 1000V Test Probes (Red/Black
  7. Blue Lead with Rear Connection
  8. 2m Mains Power Cable
  9. DataView Software Package
  10. Optical/USB Communication Lead
  11. Operating Manual (CD-ROM and Print)
  12. 5 Specification Labels

Chauvin Arnoux CA6550 Technical Specifications/Comparison Chart

The following chart outlines the functions of the CA6550 and its sister device, the CA6555.

CA6550

CA6555

Test Voltages 10kV 15kV
Test Voltages Ranges 500V: 10kΩ to 2TΩ
1000V: 10kΩ to 4TΩ
2500V: 10kΩ to 10TΩ
5000V: 10kΩ to 15TΩ
500V: 10kΩ to 25TΩ
15000V: 10kΩ to 30TΩ
Fixed Test Voltages 500 / 1,000 / 2,500 / 5,000 / 10,000 V 500 / 1,000 / 2,500 / 5,000 / 10,000 / 15,000 V
Variable Test Voltages 40 V – 10,000 V
3 Settable Voltage Values
40 V – 15,000 V
3 Settable Voltage Values
Adjustment Increment
for Variable Voltages
Variable: 40-10 kV step : 40 V-1 kV: 10 V
1 kV-10 kV: 100 V
Variable: 40-15 kV step: 40 V-1 kV: 10 V
1 kV-15 kV: 100 V
Ramp Mode 3 presettable ramps: start voltage / end voltage / duration
Ramp Configuration Mode 40-1,100 V / 500-10,000 V 40-1,100 V / 500-15,000 V
Step Mode Up to 10 steps (value and duration con gurable for each step)
Voltage Measurement After Test AC: 0 – 2,500 V / DC: 0 – 4,000 V
Capacitance Measurement 0.001-9.999 μF / 10.00-49.99 μF
Leakage Current Measurement 0 – 8 mA
Discharge After Test Yes/Automatic
Additional Test Stop Modes I-limit Programmable: 0.2-5 mA
Early Break di/dt
Timer Up to 99 minutes 59 seconds
Burning Mode Burning Constant Testing
Ratio Calculation PI, DAR, DD
Calulcation of R at ref. T° Yes
Measurement Display Filter 3 Filters with 3 Possible Time Constant
Graphs on Display R(t)+u(t); i(t); i(u);
Storage 256 recordings, 80,000 points : R, U, I and date
Communication Optically-isolated port for USB and RS232 links
PC Software DataView
Power Supply NiMH rechargeable batteries, 8x 1.2 V / 4,000 mAh
charging by external voltage: 90-260 V 50/60 Hz
Battery Charging Battery charging possible while performing insulation measurements
Electrical Safety 1,000 V CAT IV – IEC 61010-1 and IEC 61557
EMC, Mechanical Protection, Altitude EN 61326-1 , IP54 , 3,000 m
Dimensions and Weight LxWxH: 340 x 300 x 200 mm, 6.2 kg approx. (excluding accessories)

The following chart outlines the functions of the CA6550 and its sister device, the CA6555.

CA6550

CA6555

Test Voltages 10kV 15kV
Test Voltages Ranges 500V: 10kΩ to 2TΩ
1000V: 10kΩ to 4TΩ
2500V: 10kΩ to 10TΩ
5000V: 10kΩ to 15TΩ
500V: 10kΩ to 25TΩ
15000V: 10kΩ to 30TΩ
Fixed Test Voltages 500 / 1,000 / 2,500 / 5,000 / 10,000 V 500 / 1,000 / 2,500 / 5,000 / 10,000 / 15,000 V
Variable Test Voltages 40 V – 10,000 V
3 Settable Voltage Values
40 V – 15,000 V
3 Settable Voltage Values
Adjustment Increment
for Variable Voltages
Variable: 40-10 kV step : 40 V-1 kV: 10 V
1 kV-10 kV: 100 V
Variable: 40-15 kV step: 40 V-1 kV: 10 V
1 kV-15 kV: 100 V
Ramp Mode 3 presettable ramps: start voltage / end voltage / duration
Ramp Configuration Mode 40-1,100 V / 500-10,000 V 40-1,100 V / 500-15,000 V
Step Mode Up to 10 steps (value and duration con gurable for each step)
Voltage Measurement After Test AC: 0 – 2,500 V / DC: 0 – 4,000 V
Capacitance Measurement 0.001-9.999 μF / 10.00-49.99 μF
Leakage Current Measurement 0 – 8 mA
Discharge After Test Yes/Automatic
Additional Test Stop Modes I-limit Programmable: 0.2-5 mA
Early Break di/dt
Timer Up to 99 minutes 59 seconds
Burning Mode Burning Constant Testing
Ratio Calculation PI, DAR, DD
Calulcation of R at ref. T° Yes
Measurement Display Filter 3 Filters with 3 Possible Time Constant
Graphs on Display R(t)+u(t); i(t); i(u);
Storage 256 recordings, 80,000 points : R, U, I and date
Communication Optically-isolated port for USB and RS232 links
PC Software DataView
Power Supply NiMH rechargeable batteries, 8x 1.2 V / 4,000 mAh
charging by external voltage: 90-260 V 50/60 Hz
Battery Charging Battery charging possible while performing insulation measurements
Electrical Safety 1,000 V CAT IV – IEC 61010-1 and IEC 61557
EMC, Mechanical Protection, Altitude EN 61326-1 , IP54 , 3,000 m
Dimensions and Weight LxWxH: 340 x 300 x 200 mm, 6.2 kg approx. (excluding accessories)

Additional information

Weight 7000 g

Reviews

There are no reviews yet.

Be the first to review “Chauvin Arnoux CA6550 10Kv Insulation Tester Megohmmeter”

Your email address will not be published. Required fields are marked *

Contact Us banner service team