Fluke 117 Multimeter with Non-Contact Voltage Detection Fluke Test Lead Set and Protective Case LDMC27B

⚡ VoltAlert™ technology for non-contact voltage detection

⚡ AutoVolt automatic ac/dc voltage detection

⚡ Low input impedance: helps prevent false readings due to ghost voltage

⚡ 3 Year Fluke Warranty

£175.00 exc VAT / £210.00 inc VAT

Add Personalised Calibration Certificate

Product price
Additional options total:
Order total:

Description

Product Details:

The Fluke 117 has every feature you need built-in, this digital multimeter can measure AC/DC voltage, continuity, resistance, diode, capacitance, frequency and current, all with a high degree of accuracy to ensure you always get reliable results. The 117 with true RMS technology also ensures results are accurate when testing on electrically noisy or irregular AC circuits, making sure you don’t get an inaccurate reading when testing in these applications.

This digital multimeter helps you to work smarter and safer. Fluke’s VoltAlert technology gives a quick indication of the presence of AC voltage (the 117 has a built-in non-contact voltage detector) while Fluke’s AutoVolt technology will automatically determine the presence of either AC or DC voltage. A large-size LCD screen will relay all measurement results and a bright white LED backlight is included, allowing you to keep working in areas where poor lighting may be a problem.

This digital multimeter is CAT III 600V safety rated.

Key Features:

  • Designed completely to fit the demands of working commercial electricians
  • Measure AC and DC voltage to 600V with a resolution of 1mV
  • Measure AC/DC current up to 10.00A with a resolution of 1mA (DC) and 0.01A (AC)
  • Resistance measurements to 40MΩ with a resolution of 0.1Ω
  • Capacitance measurements up to 10,000μF with a resolution of 1nF
  • Frequency measurements to 50kHz with a resolution of 0.01Hz
  • VoltAlert technology – the Fluke 117 includes a built-in non-contact voltage detector
  • AutoVolt – automatically detects AC/DC voltage
  • Low input impedance helps to prevent inaccurate readings which may be caused by ghost voltage
  • Large-size LCD screen with bright white LED backlight
  • 6000 count digital display with paragraph (33 segments, updates 4 per second)
  • True RMS – ensures accuracy when testing on non-linear AC loads
  • MIN/MAX/AVG functions record the minimum, maximum and average values taken over a period of time (also shows elapsed time)
  • Compact, ergonomic design suitable for use in one hand
  • CAT III 600V safety rating
  • 400-hour typical battery life (without backlight) using 9V alkaline batteries

Fluke 117 Technical Specifications

Measurement Range Resolution Accuracy ±(% of reading + counts)
DC Millivolts 600.0mV 0.1mV 2.0% + 3
DC Voltage 6.000V 0.001V
60.00V 0.01V
600.0V 0.1V
Autovoltage 600.0V 0.1V 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC Millivolts (True RMS)¹ 6.000V 0.001V 1.0% + 3 (45 to 500Hz)
2.0% + 3 (500Hz to 1kHz)
60.00V 0.01V
600.0V 0.1V
Continuity 600Ω Beeper on < 20Ω Off > 250Ω
Detects opens or shots of 500μs or longer
Resistance 600.0Ω 0.1Ω 0.9% + 2
6.000kΩ 0.001kΩ 0.9% + 1
60.00kΩ 0.01kΩ
600.0kΩ 0.1kΩ
6.000MΩ 0.001MΩ
40.00MΩ 0.01MΩ 1.5% + 2
Diode Test 2.000V 0.001V 0.9% + 2
Capacitance 1000nF 1nF 1.9% + 2
10.00μF 0.01μF
100.0μF 9,1μF
9999μF 1μF
100μF to 1000μF 1.9% + 2
>1000μF 5% + 20
AC Current (True RMS)
45 to 500Hz
6.000A 0.001A 1.0% + 3
10.00A 0.01A
20A continuous overload for 30 seconds max
DC Current 6.000A 0.001A 1.0% + 3
10.00A 0.01A
20A continuous overload for 30 seconds max
Frequency (V or A input)² 99.99Hz 0.01Hz 0.1% + 2
999.9Hz 0.1Hz
9.999kHz 0.001kHz
50.00kHz 0.01kHz
General Specifications
Maximum Voltage Between Any Terminal and Earth Ground 600V
Surge Protection 6kV peak per IEC 61010-1 600V, CAT III, Pollution Degree 2
Fuse for A Input 11A, 1000V FAST fuse (Fluke PN 803292)
Display Digital: 6000 counts, updates 4/sec
Bargraph 33 segments, updates 32/sec
Operating Temperature -10 to +50°C
Storage Temperature -40 to +60°C
Battery 9V alkaline, NEDA 1604A/IEC 6LR61
Battery Life 400 hours typical, without backlight

¹ All ac voltage ranges are specified from 1 % to 100 % of range. Because inputs below 1 % of range are not specified,
it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected
from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full
scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.

² Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.

  • Fluke 117 Multimeter
  • Fluke Red & Black Silicone Test Lead Set
  • Holster (Rubber Shielding Around Meter)
  • User Manual
  • 9volt Alkaline Battery
  • Leaderman C27B Protective Multimeter Case