Fluke 1507 Insulation Resistance Tester with C1600 Meter and Tool Case

Fluke

£450.00 / £540.00 incl VAT

c1600 HARD CASE FOR ONLY £25
⚡ Auto-discharge of capacitive voltage for added user protection.
⚡ AC/DC voltage: 0.1 V to 600 V.
⚡ 200 mA Continuity.
⚡ Resistance: 0.01 W to 20.00 KW.
⚡ One Year Fluke Warranty.
Price Pledge

Calibration Certificate

Add Calibration to your Insulation Tester.

Description

Fluke 1507 Insulation Resistance Tester with C1600 Meter and Tool Case

Product Details:

The Fluke 1507 Insulation Testers is compact, rugged, reliable, and easy to use. With their multiple test voltages, they are ideal for many troubleshooting, commissioning, and preventative maintenance applications. Additional features, like the remote probe on these tools, save both time and money when performing tests.

Key Features:

  • Insulation test range: 1507: 0.01 MW to 10 GW.
  • Insulation test voltages: 1507: 50 V, 100 V, 250 V, 500 V, 1000 V (1507 only).
  • Save both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio.
  • Make repetitive tests simple and easy with the 1507’s Compare (Pass/Fail) function (1507 only).
  • Repetitive or hard-to-reach testing is easy with the remote test probe.
  • Live circuit detection prevents insulation tests if voltage > 30 V is detected for added user protection.
  • Auto-discharge of capacitive voltage for added user protection.
  • AC/DC voltage: 0.1 V to 600 V.
  • 200 mA Continuity.
  • Resistance: 0.01 W to 20.00 KW.
  • Save battery power with auto power off.
  • Read measurements easily with a large, backlit display.
  • CAT IV 600 V overvoltage category rating for added user protection.
  • Remote probe, test leads, probes and alligator clips included with each tester.
  • Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work.
  • Four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests.
  • One-year warranty.

Fluke C1600 Meter and Tool Box Carry Case

PRODUCT DETAILS:

The Fluke C1600 Case is a durable and versatile carrying case designed to keep your valuable tools and equipment safe and secure during transport. This rugged case is made from high-quality materials and features a hard shell exterior that can withstand the toughest conditions.

The C1600 Case has a customizable foam interior (SOLD SEPERATELY) that allows you to tailor the case to fit your specific needs. The foam interior can be easily cut to fit your tools and equipment, ensuring a snug and secure fit. This prevents your tools from moving around during transport, reducing the risk of damage or breakage.

This carrying case has a large capacity, with enough room to store a variety of tools, including multimeters, clamp meters, testers, and more. The case also features a convenient carrying handle, making it easy to transport your tools to and from job sites.

In addition to its rugged durability and customizable interior, the Fluke C1600 Case also has a sleek and professional look. The black exterior with yellow Fluke logo is both stylish and recognizable, making it a great choice for professionals who want to showcase their commitment to quality and reliability.

Overall, the Fluke C1600 Case is a top-of-the-line carrying case that offers superior protection and customization for your valuable tools and equipment. With its durable construction, customizable interior, and professional appearance, this case is a must-have for any professional who wants to keep their tools safe and organized.

Key Feature:

  • Deep interior large enough to hold and protect your meters and leaves room for accessories and other essentials.
  • Rubber gasket in lid seals out dust and keeps contents dry.
  • Lift out tray keeps everything organised.
  • Snap open compartment on top of lid for easy access to small parts such as fuses, batteries, probes and leads.
  • Includes five hook and loop straps to wrap cords and test leads when not in use.
  • Can be locked.
  • Large carry handle for easy carrying

If you require this case for your 1651 – 1652 – 1653 – 1654 – 1662 -1663 -1664  MultiFunction Tester and require the Protective Foam Base then we also supply these separately the part number is LDM165XF.

AC/DC voltage measurement

Accuracy

Range Resolution 50 Hz to 400 Hz ± (% of Rdg Digits)
600.0 V 0.1 V ± (2 % 3)
  1. Input impedance
    3 MW (nominal), < 100 pF
  2. Common mode rejection ratio (1 kW unbalanced)
    > 60 dB at dc, 50 or 60 Hz
  3. Overload protection
    600 V rms or dc

Earth bond resistance measurement

Range Resolution Accuracy1 (% of Rdg Digits)
20.00 O 0.01 O ± (1.5 % 3)
200.0 O 0.1 O
2000 O 1 O
20.00 kΩ 0.01 kΩ

1Accuracies apply from 0 to 100 % of range.

  1. Overload protection
    2 V rms or dc
  2. Open circuit test voltage
    > 4.0 V, < 8 V
  3. Short circuit current
    > 200.0 mA

Insulation specifications

  1. Measurement range
    0.01 MW to 2000 MW
  2. Test voltages
    50 V, 100 V, 250 V, 500 V, 1000 V
  3. Test voltage accuracy
    20 %, – 0 %
  4. Short-circuit test current
    1 mA nominal
  5. Auto discharge
    Discharge time < 0.5 second for C = 1 μF or less
  6. Live circuit detection
    Inhibit test if terminal voltage > 30 V prior to initialization of test
  7. Maximum capacitive load
    Operable with up to 1 μF load

Accuracy

Output Voltage Display Range Resolution Test Current Accuracy ± (% of Rdg Digits)
50 V 0.01 MΩ to 20.00 MΩ 0.01 MΩ 1 mA @ 50 kΩ ± (3 % 5)
(0 % to 20 %) 20.0 MΩ to 50.0 MΩ 0.1 MΩ
100 V 0.01 MΩ to 20.00 MΩ 0.01 MΩ 1 mA @ 100 kΩ ± (3 % 5)
(0 % to 20 %) 20.0 MΩ to 100.0 MΩ 0.1 MΩ
250 V 0.01 MΩ to 20.00 MΩ 0.01 MΩ 1 mA @ 250 kΩ ± (1.5 % 5)
(0 % to 20 %) 20.0 MΩ to 200.0 MΩ 0.1 MΩ
500 V (0 % to 20 %) 0.01 MΩ to 20.00 MΩ 0.01 MΩ 1 mA @ 500 kΩ ± (1.5 % 5)
20.0 MΩ to 200.0 MΩ 0.1 MΩ
200 MΩ to 500 MΩ 1 MΩ
1000 V (0 % to 20 %) 0.1 MΩ to 200.0 MΩ 0.1 MΩ 1 mA @ 1 MΩ ± (1.5 % 5)
200 MΩ to 2000 MΩ 1 MΩ
2.0 GO to 10.0 GO 0.1 GO ± (10 % 3)

EN61557 Specifications

The following tables are a requirement for European labeling.

Measurement Intrinsic Uncertainty Operating Uncertainty1
Volts ± (2.0 % 3) 30 %
Earth Bond Resistance ± (1.5 % 3) 30 %
Insulation Resistance Depends on test voltage and range. See Insulation Test specifications. 30 %

1This specification comes from the standard and indicates the maximum amount allowable by the standard.

EN61557 influence variables and uncertainties

Earth Bond Resistance Uncertainty for Uncertainty for
Influence Variable Designation per EN61557 Insulation Resistance Earth Bond Resistance
Supply Voltage E2 5 % 5 %
Temperature E3 5 % 5 %

1Specification confidence level 99 %.

The following tables can be used to determine the maximum or minimum display values considering maximum instrument operating error per EN61557-1, 5.2.4.

Insulation resistance maximum and minimum display values

50 V 100 V 250 V 500 V 1000 V
Minimum Minimum Minimum Minimum Minimum
Limit Value Display Limit Value Display Limit Value Display Limit Value Display Limit Value Display
Value Value Value Value Value
0.05 0.07 0.05 0.07 0.05 0.07 0.05 0.07
0.06 0.08 0.06 0.08 0.06 0.08 0.06 0.08
0.07 0.09 0.07 0.09 0.07 0.09 0.07 0.09
0.08 0.10 0.08 0.10 0.08 0.10 0.08 0.10
0.09 0.12 0.09 0.12 0.09 0.12 0.09 0.12
0.1 0.13 0.1 0.13 0.1 0.13 0.1 0.13 0.1 0.1
0.2 0.26 0.2 0.26 0.2 0.26 0.2 0.26 0.2 0.3
0.3 0.39 0.3 0.39 0.3 0.39 0.3 0.39 0.3 0.4
0.4 0.52 0.4 0.52 0.4 0.52 0.4 0.52 0.4 0.5
0.5 0.65 0.5 0.65 0.5 0.65 0.5 0.65 0.5 0.7
0.6 0.78 0.6 0.78 0.6 0.78 0.6 0.78 0.6 0.8
0.7 0.91 0.7 0.91 0.7 0.91 0.7 0.91 0.7 0.9
0.8 1.04 0.8 1.04 0.8 1.04 0.8 1.04 0.8 1.0
0.9 1.17 0.9 1.17 0.9 1.17 0.9 1.17 0.9 1.2
1.0 1.30 1.0 1.30 1.0 1.30 1.0 1.30 1.0 1.3
2.0 2.60 2.0 2.60 2.0 2.60 2.0 2.60 2.0 2.6
3.0 3.90 3.0 3.90 3.0 3.90 3.0 3.90 3.0 3.9
4.0 5.20 4.0 5.20 4.0 5.20 4.0 5.20 4.0 5.2
5.0 6.50 5.0 6.50 5.0 6.50 5.0 6.50 5.0 6.5
6.0 7.80 6.0 7.80 6.0 7.80 6.0 7.80 6.0 7.8
7.0 9.10 7.0 9.10 7.0 9.10 7.0 9.10 7.0 9.1
8.0 10.40 8.0 10.40 8.0 10.40 8.0 10.40 8.0 10.4
9.0 11.70 9.0 11.70 9.0 11.70 9.0 11.70 9.0 11.7
10.0 13.0 10.0 13.0 10.0 13.0 10.0 13.0 10.0 13.0
20.0 26.0 20.0 26.0 20.0 26.0 20.0 26.0 20.0 26.0
30.0 39.0 30.0 39.0 30.0 39.0 30.0 39.0 30.0 39.0
40.0 52.0 40.0 52.0 40.0 52.0 40.0 52.0 40.0 53.0
50.0 65.0 50.0 65.0 50.0 65.0 50.0 65.0
60.0 78.0 60.0 78.0 60.0 78.0 60.0 78.0
70.0 91.0 70.0 91.0 70.0 91.0 70.0 91.0
80.0 104.0 80.0 104.0 80.0 104.0 80.0 104.0
90.0 117.0 90.0 117.0 90.0 117.0 90.0 117.0
100.0 130.0 100.0 130.0 100.0 130.0
200.0 260.0 200.0 260.0
300.0 390.0 300.0 390.0
400.0 520.0 400.0 520.0
500.0 650.0
600.0 780.0
700.0 910.0
800.0 1040.0
900.0 1170.0
1000.0 1300.0
2000.0 2600.0

Earth bond resistance maximum display values

Limit Value Maximum Display Value
0.4 0.28
0.5 0.35
0.6 0.42
0.7 0.49
0.8 0.56
0.9 0.63
1.0 0.7
2.0 1.4
3.0 2.1
4.0 2.8
5.0 3.5
6.0 4.2
7.0 4.9
8.0 5.6
9.0 6.3
10.0 7.0
20.0 14.0
30.0 21.0
40.0 28.0
50.0 35.0
60.0 42.0
70.0 49.0
80.0 56.0
90.0 63.0
100.0 70.0
200.0 140.0
300.0 210.0
400.0 280.0
500.0 350.0
600.0 420.0
700.0 490.0
800.0 560.0
900.0 630.0
1000.0 700.0
2000.0 1400.0
  • TL224 Test Leads.
  • TP74 Test Probes.
  • Clips PN 1958654 (red) and PN 1958646 (black).
  • Holster and remote probe.
 Zone  Orders Under £75  Orders Over £75
 Zone 1 – UK Mainland Royal Mail 1st Class Delivery (1-2 Days) £5.95
Royal Mail 2nd Class Delivery (3-5 Days) £4.95
DPD Guaranteed Next Day Delivery (Orders must be placed before 2pm) £8.95
Royal Mail 2nd Class Delivery (3-5 Days) FREE
 Zone 2 – Scottish Highlands and Islands Royal Mail 1st Class Delivery (2-3 Days) £5.95
Royal Mail 2nd Class Delivery (5-6 Days) £4.95
DPD Express 2 Day Delivery (Orders must be placed before 2pm) £18.00
Royal Mail 2nd Class Delivery (5 -6 Days) FREE
 Zone 3 – Northern Ireland, Isle of Man, Isles of Scilly Royal Mail 1st Class Delivery (2-3 Days) £5.95
Royal Mail 2nd Class Delivery (5-6 Days) £4.95
DPD Express 2 Day Delivery (Orders must be placed before 2pm) £18.00
Royal Mail 2nd Class Delivery (5 -6 Days) FREE
 Zone 4 – Channel Islands Shipping is dependant on the weight of your order.
Please contact us to complete your order.
 N/A
International Shipping is dependant on the weight of your order and delivery address.
Please complete your order through the checkout or contact us to complete your order.
N/A

You may also like…