Fluke 1630 Earth Ground Clamp Meter

  • 1 Year Fluke Warranty
  • Stakeless Testing
  • 35mm Jaw
  • Ground Loop Resistance
  • TRMS AC Current up to 30A
  • Data Storage

£999.00 exc VAT / £1,198.80 inc VAT

Product price
Additional options total:
Order total:

Description

Fluke 1630 Earth Ground Clamp Meter

1 Year Fluke Warranty


Fluke 1630 Product Details:

 

Earth Ground loop resistance measurements for commercial, industrial, and utility applications

The clamp-on ground testing technique used by the Fluke 1630 simplifies ground loop testing and enables non-intrusive leakage current measurement. The compact and rugged design makes the Fluke 1630 easy to use in small places and harsh environments, while the ‘display hold’ and the continuity testing with an audible alarm function ensures convenience in use. The novel technique means that earth ground loop testing and continuity testing can be completed without breaking the circuit.

 

Fluke 1630 Comes Supplied With:

Rugged carrying case with shoulder strap

Resistance test loop

9 V battery

User’s manual in English, French, Spanish, German, Italian, Portuguese, and Simplified Chinese

 

Stakeless testing system

The Fluke 1630 uses the Stakeless testing method, which eliminates the need to disconnect parallel ground rods and find suitable locations for placing auxiliary ground stakes. This saves time and enables users such as industrial and utility electricians, and field service electricians and contractors, to perform earth ground loop tests in locations where it is not possible to use other techniques, including inside buildings or on power pylons. With the Stakeless testing method, earth ground stakes are no longer necessary. The Fluke 1630 Earth Ground Clamp is placed around the earth ground rod or the connecting cable. A known voltage is induced by one half of the clamp and the current is measured by the other half. The tester automatically determines the ground loop resistance at this grounding connection.

 

A wide ground loop resistance range, from 0.025 Ω to1500 Ω, to satisfy all requirements

Large jaw opening of 35 mm (1.38 in) for tests on ground conductors and/or equipotential bus bars

Measurement of ground leakage current, from 0.2 mA to 1000 mA, without needing to disconnect – ideal for system troubleshooting

Wide ac current measurement range from 0.2 A to 30 A allows one instrument for multiple applications

User-defined HI / LO Alarm limits, for rapid measurement evaluation

Handy ‘display hold’ button for capturing readings in hard-to-reach places

Time saving memory function automatically records and stores measured values

Automatic self calibration ensures correct measurement every time

Overload protection: 200 A

Carrying case and resistance test loop included

≥ 8 hours battery life (continuous operation)

Fluke 1630-2 Earth Ground Clamp Meter
Operating error Refers to the operating temperature range and is guaranteed for 2 years
Storage temp. range -0 °C to 60 °C (-4°F to 140 °F)
Reference temp. range 23 °C ± 5 °C (73 °F ± 9 °F)
Storage humidity <75 % Rh
Operating humidity <85% Rh
Display 999 digital LC display with special symbols
Protection IP30 according to IEC 529/EN 60529
Safety 300 V, CAT III pollution degree 2 IEC 61010-1 and IEC 61010-2-032
Weight 750 g (1.165 lbs)
Conductor size 35 mm (1.38 in) approximately
Dimension (length x width x depth) 276 mm x 100 mm x 47 mm (10.8 in x 3.9 in x 1.9 in)
Emission IEC 1000 4-2, IEC 61326-I class B
Immunity IEC 61000-4-2, 8 kV (air) criteria A
IEC 61000-4-3, 3 V/m performance criteria A
Range selection Auto
Overload indicator “OL” on display
Measuring time 0.5 sec
Measuring frequency 3.333 kHz
Battery type 9 V alkaline (type IEC 6 LR 61)
Battery life ≥ 8 hours (continuous operation)
Power consumption 40 mA
Low battery indication Display symbol

 

Ground Loop Resistance (Autorange)
Range Accuracy
(± % of reading Ω)
0.025 – 0.250 Ω ± 1.5 % rdg ± 0.02 Ω
0.250 – 9.999 Ω ± 1.5 % rdg ± 0.05 Ω
10.00 – 99.99 Ω ± 2.0 % rdg ± 0.3 Ω
100.0 – 199.9 Ω ± 3.0 % rdg ± 1.0 Ω
200.0 – 400.0 Ω ± 5.0 % rdg ± 5 Ω
400.0 – 600.0 Ω ± 10 % rdg ± 10 Ω
600.0 – 1500 Ω ± 20 %
Note: Loop resistance with no inductance, external magnetic field < 50A/m, external electrical field < 1 V/m, conductor centered.

Additional information

Weight 1500 g