Fluke 1663 Multifunction Tester with Fluke 114 Digital Multimeter & DMS Download Software

⚡ Heavy-duty mains cord with the single input connector

⚡ Z max memory

⚡ On/off switchable auto starts for RCD and loop testing

⚡ Data Management  Software (DMS)

⚡ Continuity checks at L-N, L-PE, and N-PE inputs

£675.00 exc VAT / £810.00 inc VAT

Add Personalised Calibration Certificate

Product price
Additional options total:
Order total:

Description

 

Fluke 1663 Multifunction Tester with Fluke 114 Digital Multimeter & DMS Download Software

Product Details:

The Fluke 1663 – the new, improved version of the Fluke 1653B Multifunction Tester. The Fluke 1663 includes everything a professional electrical installer needs including a huge variety of different measurement functions, built-in memory storage, and download, and fast, easy-to-configure testing procedures.

On top of these new functions you can also expect all of the typical measurements you’ll need such as voltage (AC/DC), frequency, wiring polarity, insulation resistance, loop/line resistance, prospective earth fault current (PEFC/IK), prospective short-circuit current (PSC/IK) and several RCD measurement modes such as RCD trip time, ramp test (RCD trip current) and more.

Thanks to built-in memory storage, the Fluke 1663 makes it significantly easier to log your testing results (ideal for jobs where you’ll be testing a wide variety of different electrical installations). This data can be stored and viewed back on the tester or can be transferred across to PC and interacted with further using either FlukeView or Fluke DMS software packages (sold separately).

Key Features:

  • Suitable for testing smooth, DC-sensitive RCDs (Type B/B+)
  • True RMS AC/DC voltage measurements
  • Frequency measurements
  • Wiring polarity checker – detects broken PE and N wires
  • Insulation resistance measurements
  • Continuity and resistance measurements – includes motor winding testing with continuity test at 10mA
  • Loop and line resistance measurements
  • Prospective earth fault current (PEFC/IK) measurements
  • Prospective short-circuit current (PSC/IK) measurements
  • RCD trip time function
  • RCD trip current (ramp test)
  • Measure trip time and current for A/AC type RCDs in one test
  • RCD variable test current
  • Automatic RCD test sequence
  • Phase sequence test
  • Self-testing function
  • Illuminated display for use in different lighting conditions
  • Integrated memory for storing data
  • IR-USB interface for download to PC (requires the use of optional Fluke DMS or FlukeView Software packages to view data – sold separately)
  • Remote probe makes it easier to activate testing results without holding the tester

AC voltage measurement

  • Range: 500V
  • Resolution: 0.1V
  • Accuracy 45Hz – 66Hz: 0.8% + 3 counts
  • Input impedance: 360kΩ
  • Overload protection: 660V rms

Continuity testing RLO

  • Range (autoranging): 20Ω / 200Ω / 2000Ω
  • Resolution: 0.01Ω / 0.1Ω / 1Ω
  • Open circuit voltage: >4V

Insulation resistance measurement

  • Test voltages:  50-100-250-500-1000V
  • Accuracy of tTest voltage (at rated test current): +10%, -0%
  • Test voltage: 50V; 100V; 250V; 500V; 1000V
  • Insulation resistance range: 20 to 50MΩ; 20 to 100MΩ; 20 to 200MΩ; 20 to 200 to 500MΩ; 20 to 200 to 1000MΩ
  • Resolution: 0.01MΩ / 0.1MΩ; 0.01MΩ / 0.1MΩ; 0.01MΩ / 0.1MΩ; 0.01MΩ / 0.1MΩ / 1MΩ; 0.01MΩ / 0.1MΩ / 1MΩ
  • Test current: 1mA @ 50kΩ; 1mA @ 100kΩ; 1mA @ 250kΩ; 1mA @ 500kΩ; 1mA @ 1MΩ

Loop and line impedance (ZI)

  • Range: 10Ω / 0.001Ω / High current mΩ mode
  • Resolution: 0.01Ω / 0.1Ω / 1Ω

Prospective earth fault current, PSC test

  • Range: 1000A / 10kA (50kA)
  • Resolution: 1A / 0.1kA
  • Computation: Prospective earth fault current (PEFC) or prospective short current (PSC) calculated by splitting actual mains voltage by measured loop (L-PE) resistance or line (L-N) resistance respectively

RCD testing, RCD types tested

  • RCD type: AC1; G2, S3
  • Model 1663: A4, AC1, G2, S3

Notes: 1Responds to AC; 2General no delay; 3Time delay; 4Responds to pulsed signal

Tripping speed test (ΔT)

  • Current settings1: 10-30-100-300-500-1000mA – VAR; 10-30-100mA
  • Multiplier: x0.5, x 1; x5
  • Measurement range: 310ms, 50ms (RCD Type G); 510ms, 160ms (RCD Type)

Notes: 11000mA with type AC only, 700mA maximum type A in VAR mode, VAR mode not available for type B

RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)

  • Current range: 30% to 110% of RCD rated current1
  • Step size: 10% of IΔN2
  • Dwell time: 300ms/step (Type G); 500ms/step (Type S)
  • Measurement accuracy: ±5%
  • Specified trip current ranges (EN 61008-1): 50% to 100% for Type AC; 35% to 140% for Type A (>10 mA); 35% to 200% for Type A (≤10 mA); 50% to 200% for Type B; ²5% for Type B

Notes: ¹30% to 150% for Type A IΔN > 10 mA; 30% to 210% for Type A IΔN = 10 mA; 20% to 210% for Type B

Earth Resistance Test (RE)

  • Range: 200Ω / 2000Ω
  • Resolution: 0.1Ω / 1Ω
  • Frequency: 128Hz
  • Output voltage: 25V

General

  • Size (L x W x H): 10 x 25 x 12.5cm
  • Weight (incl. batteries): 1.3kg
  • Batteries:  6 x AA
  • Sealing: IP-40
  • Safety: Meets requirements for EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition
  • Overvoltage: Cat III to 500V; Cat IV to 300V
  • Performance: EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition
  • Fluke 1663 Multifunction Installation Tester
  • CD and instruction manual for Fluke 1663 Multifunction Installation Tester
  • 6 x AA batteries
  • C1600 hard carry case
  • Zero adapter
  • Heavy-duty mains cord
  • Standard test lead set
  • Padded carrying waist and neck strap
  • Remote control probe
  • Fused test probe set
  • Fluke 1663 Quick reference guide
  • Fluke calibration certificate
  • Fluke 114 Multimeter
  • Fluke DMS

Reviews

There are no reviews yet.

Be the first to review “Fluke 1663 Multifunction Tester with Fluke 114 Digital Multimeter & DMS Download Software”

Contact Us banner service team