Fluke True-RMS 115 Digital Multimeter C115 Carry Case

⚡ Compact true-RMS meter

⚡ All you need for general electrical and electronic testing

⚡ Engineered by Fluke, with a three-year warranty

⚡ Large white LED backlight to work in poorly lit areas

⚡ Resistance and continuity

SKU: FLU-115-C115 Categories: ,

£169.99 exc VAT / £203.99 inc VAT

98 in stock

Add Personalised Calibration Certificate

Product price
Additional options total:
Order total:

Description

  

Product Details :

For general purpose electrical and electronic test requirements, the Fluke 115 true-rms digital multimeter provides the perfect answer. Its simple operation, compact design and ease of use makes it perfect for quick verification and field service use.

  • Compact true-rms meter
  • All you need for general electrical and electronic testing
  • Engineered by Fluke, with a three-year warranty
  • Large white LED backlight to work in poorly lit areas
  • Resistance and continuity
  • Frequency and capacitance
  • Maximum Voltage ac/dc 600V
  • 10A ac/dc current measurement (20 A overload for 30-seconds max)
  • Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated

Safety Conformance

All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE.

The Fluke 115 displays true-rms voltage and current readings with 6000 count resolution, tests diodes, frequency, continuity and capacitance and provides Min/Max/Average readings to record signal fluctuations. A large white LED backlight aids work in poorly lit areas. Its easy-open battery access door makes battery changes a snap. Fluke 115 multimeters are independently tested for safe use in CAT III 600V environments.

 

Specifications

Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display
Digital: 6,000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating Temperature
-10 °C to + 50 °C
Storage Temperature
-40 °C to + 60 °C
Battery type
9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
400 hours typical, without backlight

Accuracy Specifications

DC millivolts
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.00 V / 0.1 V
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 true-rms
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range: 600 Ω
Resolution: 1 Ω
Accuracy: Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer.
Ohms
Range/Resolution: 600.0 Ω / 0.1 Ω
Range/Resolution: 6.000 kΩ / 0.001 kΩ
Range/Resolution: 60.00 kΩ / 0.01 kΩ
Range/Resolution: 600.0 kΩ / 0.1 kΩ
Range/Resolution: 6.000 MΩ / 0.001 MΩ
Accuracy: 0.9 % + 1
Range/Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 5 % + 2
Diode Test
Range/Resolution: 2.00 V / 0.001 V
Accuracy: 0.9% + 2
Capacitance
Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 µF / 0.01 µF
Range/Resolution: 100.0 µF / 0.1 µF
Range/Resolution: 9999 µF / 1 µF
Range/Resolution: 100 µF to 1000 µF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 µF
Accuracy: 5% + 20%
Lo-Z Capacitance
Range: 1 nF to 500 µF
Accuracy: 10% + 2 typical
AC amps true-rms (45 Hz to 500Hz)
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.5% + 3
20 A overload for 30-seconds max
DC amps
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.0% + 3
20 A overload for 30-seconds max
Hz (V or A input)2
Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.9 Hz / 0.01 Hz
Range/Resolution: 9.999 kHz / 0.001 kHz
Range/Resolution: 50 kHz / 0.01 kHz
Accuracy: 0.1% + 2

Notes:

1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage.

Mechanical & General Specifications

Size
167 x 84 x 46 mm (6.57″ x 3.31″ x 1.82″)
Weight
550 g
Warranty
3 years
Contact Us banner service team