Kewtech IR1200 Dual-Channel Infrared Thermometer
- Supplied with a K-type thermocouple (range: -40°C to +250°C)
- Measure temperatures up to 1000°C via the thermocouple channel (probe dependent)
- Can conduct IR, non-contact measurements up to 1200°C
- Two-dot laser guide clearly indicates the measurement area
£86.99 exc VAT / £104.39 inc VAT
Description
The Kewtech IR1200 Dual-Channel Infrared Thermometer is specifically designed for electricians and is capable of taking non-contact (IR) and contact temperature measurements. It will conduct measurements in °C as default, however, a °F scale is also available.
PLEASE NOTE: FOR INDUSTRIAL USE – NOT SUITABLE FOR TESTING BODY TEMPERATURE.
PLEASE SEE OUR LISTING FOR THE MEDICAL FOREHEAD AND BODY TEMPERATURE THERMOMETER
CLICK: www.testermans.co.uk/product/medical-forehead-body-temperature-infrared-thermometer
Key Benefits:
- Infrared thermometers take an average reading across a circular area, but the IR1200’s two dot laster guidance clearly defines this area so you know exactly what you are measuring.
- Measures up to 1200°C
Features:
- Specifically designed for electricians
- Capable of taking non-contact (IR) and contact temperature measurements
- °C (default) and °F scales available
- Can conduct IR, non-contact measurements up to 1200°C
- Two-dot laser guide clearly indicates the measurement area
- Second, the thermocouple channel
- Supplied with a K-type thermocouple (range: -40°C to +250°C)
- Measure temperatures up to 1000°C via the thermocouple channel (probe dependent)
- Ambient Air Temperature function: -20°C to +70°C
- Resolution: 0.1°C
- Hold function
- Min, Max, Ave and Diff functions
- Programmable high and low alarms
- Adjustable emissivity: 0.05 to 1.00
- A reliable, adaptable and versatile non-contact (IR) and contact thermometer
What’s Included?:
- Kewtech IR1200 Dual-Channel Infrared Thermometer
- K-type Thermocouple
- Battery
- Operating Instructions
Specifications:
Infrared temperature range | -5°C to 1200°C |
Ambient air function | -20°C to 70°C |
Thermocouple channel | -50°C to 1000°C |
Accuracy at calibration point | -50°C to 0°C +/- 2.4°C |
0°C to 100°C +/- 2.0°C | |
100°C to 600°C +/- 3.0°C | |
Resolution | 0.1°C |
Fahrenheit scale option | Yes |
Max, Min, Diff, Ave reading | Yes |
Alarm | High and low |
Emissivity | 0.05 to 1.00 |
Distance to spot ratio | 12 |
Laser pointer | Two-point guidance |
Data hold function | Yes |
K Type Ni-Cr & Ni-Si sensor | -40°C to 250°C |
Dimensions | 153 x 130 x 42 mm |
Weight | 146 g (without battery) |
Additional information
Weight | 1000 g |
---|

Reviews
There are no reviews yet.