Megger MFT1741+ 18th Edition Compliant Multifunction Tester

⚡ Troubleshoot and verify the installation and safety of industrial, commercial and fixed wiring installations

⚡ Includes all the tests required to complete the necessary electrical certification for the aforementioned electrical systems

⚡ Ideal for testing low voltage electrical installations in areas with high electrical noise

⚡ Suitable for conducting full single- and three-phase compliant insulation testing

⚡ Conduct single- and three-phase RCD testing between 10mA and 1A

£1,040.00 exc VAT / £1,248.00 inc VAT

5 in stock

Add Personalised Calibration Certificate

Product price
Additional options total:
Order total:

Description

Product Details:

The Megger MFT1741+ Multifunction Tester is suitable for conducting full single- and three-phase insulation testing. As indicated above it is able to conduct single- and three-phase RCD testing between 10mA and 1A.

The Megger MFT1741+ Multifunction Tester’s NEW non-trip loop impedance testing technology also enables loop impedance testing of 10mA type AC and A RCDs. Additionally, NEW non-trip loop impedance technology prevents RCDs from influencing the total loop impedance value and increases the speed of testing: non-trip loop impedance tests can be performed in eight seconds.

Furthermore, loop impedance tests are accompanied by a Confidence Meter, a NEW feature present on the Megger MFT1741+ Multifunction Tester. The meter will indicate the degree of confidence in the accuracy of the loop impedance measurement. This feature is useful as loop impedance values are particularly susceptible to changes in circuit noise. The Confidence Meter is designed to improve reliability; the digital ARC indicates the analytical process, and the measurement is continually monitored and adjusted in reference to the circuit noise.

 

Key Features:

  • Non-trip loop impedance technology
  • Test 10mA type AC and A RCDs
  • Prevents RCDs from influencing total loop impedance values
  • Non-trip loop impedance tests can be performed in eight seconds
  • Confidence Meter: indicates the confidence in the accuracy of the loop impedance result
  • Confidence Meter improves reliability: digital ARC indicates the analytical process, and the measurement is continually monitored and adjusted in reference to the circuit noise
  • Test EVSE RCDs
  • Automatic test sequences for EVSE RCDs
  • NEW 6mA DC test (requires OPTIONAL accessory) for testing EVSE RCDs
  • Large, clear backlit display
  • Digital/ analogue arc indicates fluctuating readings
  • Dual digital readout: indicates the precise reading and the test parameters simultaneously
  • Internal memory: capacity for 1000 readings
  • Download measurements via Bluetooth
  • Colour coded function controls
  • No complicated screens
  • No hidden menus
  • Ambidextrous design: TEST and LOCK buttons on either side of the unit
  • Automatic test start: frees up the user’s hands for holding probes
  • Can stand independently
  • Can be hung around the operator’s neck using the included neck strap
  • Internal rechargeable batteries: recharge in under four hours
  • Rubber over-mould for protection in tough environments
  • IP54
  • EN61010 CAT IV safety rated: can withstand accidental misuse and voltage transients
  • Can be connected anywhere within the low voltage network on single and three-phase systems
  • Visual and audible warning when hazardous voltages are detected
  • Displays the voltage value when a live voltage is detected during insulation and continuity tests
  • When the detected voltage exceeds a safe level testing will be stopped and a warning beep is issued
  • A versatile, practical and reliable electrical tester
Insulation Test
Output voltage -0% +20% at rated load or less
Voltage display ±3% ±3 digits ±0.5% of rated voltage
Short circuit current 1.5 mA nominal test current
Test current on load 1 mA at min pass values of insulation
Insulation Accuracy
1000 Volts 10 kΩ ~ 999 MΩ ±3% ±2 digits
500 Volts 10 kΩ ~ 500 MΩ ±3% ±2 digits
>500 MΩ ±10% ±4 digits
250 Volts 10 kΩ ~ 250 MΩ ±3% ±2 digits
>250 MΩ ±10% ±4 digits
100 Volts 10 kΩ ~ 100 MΩ ±3% ±2 digits
>100 MΩ ±10% ±4 digits
Resistance and Continuity
0.01 Ω ~ 99.9 Ω ±2% ±2 digits
100 Ω ~ 99.9 kΩ ±5% ±2 digits
Open circuit voltage 5 V ±1 V
Test current (user selectable) (0 Ω ~ 2 Ω)
205 mA ±5 mA
15 mA ±5 mA (user selectable)
Loop Test
Live to earth/neutral supply 48 V ~ 280 V (45 Hz ~ 65 Hz)
Live to live supply 48 V ~ 500 V (45 Hz ~ 65 Hz)
L-N/L-L tests ±5% ±5 digits
L-E tests 0.1 Ω ~ 39.9 Ω ±5% ±5 digits ± noise margin
40.0 Ω ~ 1000 Ω ±10% ±5 digits
Display range 0.01 Ω ~ 1000 Ω
Live to earth PFC range 20 kA
Live to live PSCC range 20 kA
Notes † Reference conditions apply

For test environments see service data

RCD Tests
Supply up to 100 mA 48 V ~ 480 V (45 Hz ~ 65 Hz)
Supply up to 1 A 48 V ~ 280 V
RCD type Type AC, A, S
Type B (pure dc)
No trip test (1/2xI) –10% ~ –0%
Trip test (1xI, 2xI and 5xI)+0% ~ +10%
EV 30 mA ac, 6 mA dc (Mode 1 + 2)
(Mode 1 + 2) Ramp Test
Touch voltage (0 ~ 253 V) +5% +15% ±0.5 V
Trip time ±1% ±1 ms
Trip current ±5%
Step Increments
VAR (variable RCD selection) 10 mA ~ 50 mA 1 mA steps
50 mA ~ 500 mA 5 mA steps
500 mA ~ 1000 mA 10 mA steps
Supply Measurement
Voltage 10 V ~ 600 V
(15 ~ 400 Hz) True RMS
±3% ± 1 V ±2 digits
Phase rotation indication L1–L2–L3 and L1–L3–L2
Frequency 15 Hz ~ 99 Hz ±0.5% ±1 digit
100 Hz ~ 400 Hz ±2.0% ±2 digits
Frequency resolution 0.1 Hz
Power Supply
Batteries IEC LR6 type AA alkaline (6 cells – supplied) or 1.2 V NiMH (rechargeable pack of 6 – supplied)
Mains charger for on-board re-charging (4 hours typical) 12 V car charger (cigar lighter lead – optional)
Earth/ Ground Test
Resolution 0.01 Ω
Current 0.45 mA or 4.5 mA
Noise rejection 20 V pk/pk (7 V rms)
Max probe resistances Rp and Rc
100 kΩ @ 50 V
5 kΩ @ 25 V
2 and 3 pole method (0.01 Ω ~ 1.999 kΩ)
±2.0% ±5 digits
ART method (1.00 Ω ~ 1.999 kΩ)
±5.0% ±5 digits*
Stakeless method (1.00 Ω ~ 199 Ω)
±7.0% ±5 digits*
Current
(via optional clamp meter) ±5.0% ±3 digits.
Range 0.1 mA to 200 A ac
Resolution 0.1 mA
mV Sensor Input
Including temperature (third party module) ±1.0% ±2 digits
Range 0.0 mV to ±199.9 mV dc
Resolution 0.1 mV
Data storage
Capacity 1000 results
Bluetooth® communication
Safety IEC 61010-1:2010
IEC 61010-30:2010
IEC 61010-031:2008
600 V CAT III / 300 V CAT IV
(Max Phase to Phase 600 V)
IEC 61557:2007 parts 1 to 10
EMC IEC61326 edition 2 location class B
Operating temperature range and humidity -10 °C ~ +55 °C
90% R.H. at +40 °C max
Storage temperature range and humidity -25 °C ~ +70 °C
Maximum altitude 2000 m
Weight (instrument and case) 1 kg (with batteries, excluding case)
Dimensions (instrument and case) 220 mm H x 390 mm W x 285 mm D
IP rating IP54
Calibration temperature +20 °C
Temperature coefficient <0,1% per °C For test environments see service data.
  • Megger MFT1741+ Multifunction Tester
  • Printed Quick Start Guide
  • Full User Guide (CD)
  • Calibration Certificate
  • Megger SP5 Switched Probe
  • Megger Neck Strap
  • 3-Wire Lead Set with Prods and Clips
  • Mains Plug Test Lead (BS1363)
  • AC Battery Charger
  • Large Soft Pouch with Extra Storage

Reviews

There are no reviews yet.

Be the first to review “Megger MFT1741+ 18th Edition Compliant Multifunction Tester”