Metrohm E3511 5kV Insulation Resistance Tester

  • Maximum voltage measurement of 1000 V
  • Insulation range of 100kΩ to 100GΩ
  • Rechargeable NiMH battery included

£1,813.50 exc VAT / £2,176.20 inc VAT

Product price
Additional options total:
Order total:

Description

Martindale Part No: METE3511 – Metrohm E3511 5kV Insulation Tester


Having both battery and mains operation and four selectable DC test voltages (500V, 1kV, 2.5kV & 5kV), this 5kV Insulation Tester measures insulation resistance from 100kΩ to 100GΩ.

The large, clear analogue scale also displays AC or DC voltage up to 1000V. Latching test switch allows hands-free testing.

With full over-voltage and over-current protection for measurements. 4-16 hours operation from re-chargeable NiMH batteries, the E3511 comes complete in a rugged carry case. Standard accessories include locking 2m test leads with prods and clips.

To See Specifications for this Tester please click the appropriate Tab above.

Martindale Metrorohm E3511 5kV Analogue Insulation Tester Key Features

  • Measures insulation resistance levels from 100k to 100GΩ
  • Built into its own protective carrying case with handle
  • Analogue display of testing values
  • Four selectable DC voltages of 500V, 1kV, 2.5kV and 5kV
  • AC/DC voltage measurements up to 1000V
  • Full overvoltage and current protection
  • 16 hour operation via rechargeable batteries

Full List of Products Included

  • Martindale Metrohm E3511 5kV Analogue Insulation Tester
  • 2m Test Leads
  • Probes
  • Clips

Martindale Metrohm E3511 Technical Specifications

ENVIRONMENTAL
Operating Temperature Range 15°C to +55°C
Storage Temperature Range -25°C to +65°C
Cold Temperature To IEC68-2-1
Dry Heat To IEC68-2-2
Damp Heat To IEC68-2-3
ELECTRICAL
Insulation Resistance Range 100kΩ to 100GΩ
Insulation Range Accuracy ±1.5% of scale length
Insulation Range Temperature Coefficient <0.04% of scale
length
Voltage Range 1000 volts AC or DC
Voltage Range Accuracy ±1.5% of scale length
Test Voltages 500V, 1kV, 2.5kV, 5kV DC
Test Voltage Accuracy ±5% at 10MΩ
Break Point Current 0.5mA nominal
Short Circuit Current 1.2mA nominal
Ripple Voltage <10V peak to peak (R<10MΩ)
Capacitor Charging Time 15 seconds nominal to charge a
2μF capacitor to 5kV
Capacitor Discharge Time 2 seconds nominal to discharge a
2μF capacitor from 5kV to 50V
Hum Rejection 2mA RMS on 5kV range
Maximum Voltage on Measurement Terminals 1kV across H
and L terminals;
1kV across H and guard; 250V across L and guard
Internal Battery 12V, 3AH, NiMH
Pack Battery Low Voltage 10.5 volts nominal
Maximum Battery Consumption 400mA
Battery Life 4 – 16 hours typical
Internal Power Supply/Charger 240VAC, ±10%, 50/60Hz,
18VA or 120VAC, ±10%
Protection Over-voltage and over-current protection on
measurement terminals; VDR on power inlet socket;
GDT on L terminal
Safety EMC: Meets EN 50081-1, EN 50082-1
LVD: Meets BS EN 61010
Fuses 0.2A, F, HBC, ceramic, DIN fuse on power inlet;
0.63A, T, HBC, ceramic, DIN fuse on battery
MECHANICAL
Dimensions 330mm (L) x 263mm (W) x 144mm (H)
Case Material Yellow ABS, black and clear polycarbonate
Weight 4.2kg (with batteries)

Martindale Metrohm E3511 Technical Specifications

ENVIRONMENTAL
Operating Temperature Range 15°C to +55°C
Storage Temperature Range -25°C to +65°C
Cold Temperature To IEC68-2-1
Dry Heat To IEC68-2-2
Damp Heat To IEC68-2-3
ELECTRICAL
Insulation Resistance Range 100kΩ to 100GΩ
Insulation Range Accuracy ±1.5% of scale length
Insulation Range Temperature Coefficient <0.04% of scale length
Voltage Range 1000 volts AC or DC
Voltage Range Accuracy ±1.5% of scale length
Test Voltages 500V, 1kV, 2.5kV, 5kV DC
Test Voltage Accuracy ±5% at 10MΩ
Break Point Current 0.5mA nominal
Short Circuit Current 1.2mA nominal
Ripple Voltage <10V peak to peak (R<10MΩ)
Capacitor Charging Time 15 seconds nominal to charge a
2μF capacitor to 5kV
Capacitor Discharge Time 2 seconds nominal to discharge a
2μF capacitor from 5kV to 50V
Hum Rejection 2mA RMS on 5kV range
Maximum Voltage on Measurement Terminals 1kV across H
and L terminals;
1kV across H and guard; 250V across L and guard
Internal Battery 12V, 3AH, NiMH
Pack Battery Low Voltage 10.5 volts nominal
Maximum Battery Consumption 400mA
Battery Life 4 – 16 hours typical
Internal Power Supply/Charger 240VAC, ±10%, 50/60Hz,
18VA or 120VAC, ±10%
Protection Over-voltage and over-current protection on
measurement terminals; VDR on power inlet socket;
GDT on L terminal
Safety EMC: Meets EN 50081-1, EN 50082-1
LVD: Meets BS EN 61010
Fuses 0.2A, F, HBC, ceramic, DIN fuse on power inlet;
0.63A, T, HBC, ceramic, DIN fuse on battery
MECHANICAL
Dimensions 330mm (L) x 263mm (W) x 144mm (H)
Case Material Yellow ABS, black and clear polycarbonate
Weight 4.2kg (with batteries)

Additional information

Weight 9000 g

Reviews

There are no reviews yet.

Be the first to review “Metrohm E3511 5kV Insulation Resistance Tester”

Your email address will not be published. Required fields are marked *

Contact Us banner service team