Beha-Amprobe ProInstall 75-UK Multifunction Installation Tester

⚡ FREE PAT ADAPTOR WORTH £40 WITH EVERY SALE (Enables easy Pat Testing with an Insulation / Continuity Tester or a Multifunction Tester)

⚡ The Amprobe ProInstall 75 UK multifunction installation tester, made for those who need a flexible, compact and user-friendly tester.

⚡ The ProInstall 75-UK is capable of testing many electrical applications in a variety of environments ranging from domestic, commercial and industrial.

⚡ Two Year Amprobe Warranty

£545.00 exc VAT / £654.00 inc VAT

Out of stock

Description

Product Details 

The Amprobe ProInstall 75 UK multifunction installation tester, made for those who need a flexible, compact and user-friendly tester.

The ProInstall 75-UK is capable of testing many electrical applications in a variety of environments ranging from domestic, commercial and industrial. Also, the ProInstall 75-UK is ideal for ensuring that fixed wiring is installed safely and is compliant with IEC 60364, HD 384 and BS7671 17th Edition wiring regulation standards.

A compact and functional design, large display with a wide viewing angle, easy-to-operate controls and padded neck strap not only makes the ProInstall 75-UK comfortable enough to use all day but also allows for simple, fast and easy testing. 

Key Features

  • Voltage & Frequency
  • Wiring polarity checker 
  • Insulation Resistance
  • Continuity & Resistance
  • Loop & Line Resistance
  • Prospective Earth Fault Current (PEFC/IK)
  • Prospective Short-Circuit current (PSC/IK)
  • RCD switching time, tripping level (ramp test), variable current
  • Automatic RCD test sequence
  • Test pulse current sensitive RCDs (Type A)
  • Phase Sequence Indicator
Size 10cm (L) x 25cm (W) x 12.5cm (H)
Weight (with Batteries) 1.3kg
Battery 6 x AA. Alkaline supplied. Usable with 1.2V NiCd or NiMH batteries (not included)
Battery Life (Typical) 200 hours idling
Fuse T3.15 A, 500 V, 1.5 kA 6.3 x 32 mm (PN 2030852)
Operating Temperature -10 to 40°C
Storage Temperature -10 to 60°C indefininitely (to -40°C for 100 hours)
Relative Humidity Non-condensing 80%: 10 to 35°C
70%: 35 to 40°C
Operating Altitude 0 to 2000m
Shock, Vibration Vibration to Class 3 per Mil-Prf-28800F 1 meter drop test, six sides, oak floor
Sealing IP40
EMC Complies with EN61326-1: 2006
Safety Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ ISA
-s82.02.01 2000 and CAN/CSA c22.2 No.1010 2nd edition Overvoltage
Category III (CAT III), 500 V Measurement Category III is for
measurements performed in the building installation. CAT IV, 300V.
Examples are distribution panels, circuit breakers, wiring and cabling.
Performance EN61557-1, EN61557-2, EN61557-3, EN61557-4, EN61557-5,
EN61557-6, EN61557-7 Second edition. EN61557-10 First edition.
Maximum Voltage Between Any Terminal and Earth Ground 500V
Surge Protection 6 kV peak per EN 61010-1 Ed. 2.0 (2001-02)
AC Voltage Measurement (V)
Display Range Resolution Accuracy 50Hz to 60Hz Input Impedance Overload Protection
0 to 500V 0.1V 0.8% + 3 3.3MΩ 600V RMS
Continuity Testing (RLo)
Display Range (Autoranging) Resolution Open Circuit Voltage Accuracy Range RLo Test Current
0 to 20Ω 0.01Ω >4V ±(1.5% + 3 digits) 7.5 210mA
200Ω 0.1Ω >4V ±(1.5% + 3 digits) 35 100mA
2000Ω >4V ±(1.5% + 3 digits) 240 20mA
2000 2mA
Test Probe Zeroing Press the (zero) button to zero the test probe. Can subtract up to 2 Ω of lead resistance. Error message for >2 Ω.
Live Circuit Detection Inhibits test if terminal voltage >10 V ac detected prior to initiation of test.
Insulation Resistance Measurements (Riso)
Test Voltages 250, 500, 1000V
Accuracy of Test Voltage (At Rated Test Current) +10%, -0%
Test Voltage Insulation Resistance Range Resolution Test Current Accuracy
50V 10 kΩ to 50 MΩ 0.01 MΩ 1mA @ 50kΩ ±(3 % + 3 digits)
100V 100 kΩ to 20 MΩ 0.01 MΩ 1mA @ 100kΩ ±(3 % + 3 digits)
20 MΩ to 100 MΩ 0.1 MΩ ±(3 % + 3 digits)
250V 10 kΩ to 20 MΩ 0.01 MΩ 1mA @ 250kΩ ±(1.5% + 3 digits)
20 MΩ to 200 MΩ 0.1 MΩ ±(1.5% + 3 digits)
500V 10 kΩ to 20 MΩ 0.01 MΩ 1mA @ 500kΩ ±(1.5% + 3 digits)
20 MΩ to 200 MΩ 0.1 MΩ ±(1.5% + 3 digits)
200 MΩ to 500 MΩ 1 MΩ ±10%
1000V 100 kΩ to 200 MΩ 0.01 MΩ 1mA @ 1MΩ ±(1.5% + 3 digits)
200 MΩ to 1000 MΩ 1 MΩ ±10%
Auto Discharge Discharge time constant <0.5 second for C=1μF or less
Live Circuit Detection Inhibits test if terminal voltage >30V prior to initiation of test
Maximum Capacitive Load Operable with up to the 5μF load
Loop and Line Impedance (Zl), No Trip and Hi Current Modes RCD/FI
Mains Input Voltage Range 100 to 500V AC (50/60Hz)
Input Connection (Soft Key Selection) Loop Impedance: Phase to Earth
Line Impedance: Phase to Neutral
Limit on Consecutive Tests Automatic shutdown when internal components are too hot.
There is also a thermal shutdown for RCD tests
Maximum Test Current at 400V 20A sinusoidal for 10ms
Maximum Test Current at 230V 12A sinusoidal for 10ms
Range Resolution Accuracy
10Ω 0.001Ω Hi Current Ω: ±2% +15 digits)
No Trip Mode: ±3% + 6 digits
20Ω 0.01Ω Hi Current Mode: ±(2% + 4 digits)
200Ω 0.1Ω No-Trip Mode: ±(3%)
Hi Current Mode: ±2%
2000Ω ±6%**
Notes * Valid for resistance of neutral circuit <20 Ω and up to a system phase angle of 30°. Test leads must be zeroed before testing. ** Valid for mains voltage >200 V.
Prospective Earth Fault Current Test (PSCI/Ik)
Resolution and Units Resolution Units
IK < 1000A 1A
IK > 1000A 0.1kA
Computation Prospective Earth Fault Current (PEFC/IK) or Prospective Short Circuit Current (PSC/IK) determined by dividing
measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
Range 0 to 10 kA or 0 to 50 kA (See Power-On Options earlier in this manual)
Accuracy Determined by accuracy of loop resistance and mains voltage measurements.
RCD Testing
Types Tested AC1, AC, A4, A, G2, S3, G, S
Test Signals
AC The waveform is a sinewave starting at zero crossing, polarity determined by phase selection (0° phase starts with low to high zero
crossing, 180° phase starts with high to low zero crossing). The magnitude of the test current is IΔn x Multiplier for all tests.
A The waveform is a half wave rectified sinewave starting at zero, polarity determined by phase selection (0° phase starts with low to
high zero crossing,180° phase starts with high to low zero crossing). The magnitude of the test current is 2.0 x IΔn (rms) x Multiplier
for all tests for IΔn = 0.01A. The magnitude of the test current is 1.4 x IΔn (rms) x Multiplier for all tests for all other IΔn ratings.
B Smooth DC current according to EN61557-6 Annex A
  • Beha-Amprobe ProInstall-75-UK
  • Test Lead Set
  • Alligator Clips
  • Test Probe
  • ProInstall-TL-Kit
  • Remote Test Probe/Tips
  • TL-75 Fused Test Probe
  • Zero-Adapter
  • Soft Case with Carrying Strap
  • Carry Strap for Neck/Waist