Kewtech EZYPAT PAT Tester Essential KIT1 – 5th Edition Compliant


£479.00 / £574.80 incl VAT
- 2 Year Warranty
- Performs all tests to the IET Code of Practice
- 200mA Earth continuity test
- Pass & Fail Labels PLUS Microwave Tester
- LCD screen turns green for PASS and red for FAIL
Only 1 left in stock (can be backordered)
Description
Kewtech EZYPAT PAT Tester KIT1 – 5th Edition Compliant
This Kewtech EZYPAT PAT Tester kit is a complete, all-in-one solution for Portable Appliance Testing (PAT), designed for both professionals and those new to testing. This comprehensive kit provides everything required to carry out accurate, efficient, and fully compliant PAT testing straight out of the box.
At the centre of the kit is the Kewtech EZYPAT PAT Tester, a compact and battery-operated tester built for manual dead testing of Class I and Class II appliances, as well as extension leads. Its simple interface, automatic test sequences, and clear PASS/FAIL indication make it fast and easy to use in any environment.
To extend testing capability, the kit also includes the Leaderman LDM-MLD Microwave Leakage Detector, allowing accurate detection of microwave leakage to ensure appliance safety and compliance. For organisation and traceability, the kit is supplied with high-visibility PASS and FAIL labels, along with the Leaderman LDM-PR PAT Test Report Pad for structured record keeping.
Together, these components create a practical and reliable PAT testing kit suitable for on-site engineers, contractors, landlords, and maintenance professionals.
Key Features:
PAT Tester
- Battery-operated tester for manual dead testing
- Suitable for Class I, Class II appliances and extension leads
- Automatic test sequences for fast operation
- Large backlit display with PASS (green) / FAIL (red) indication
- Up to approximately 1400 tests per battery set
- 200mA earth continuity testing
- Insulation testing at 250V and 500V DC
- Substitute leakage testing
- IT-safe low current testing
- Appliance status pre-check function
- Test lead null feature for improved accuracy
- Lightweight, compact, and easy to use
- Compatible with the KEWPAT App for reporting
Microwave Leakage Detector (LDM-MLD)
- Detects microwave leakage quickly and accurately
- Measurement range: 0 to 0.99 mW/cm²
- Audible alarm and flashing red LED when leakage is detected
- Alarm threshold at 5.0 mW/cm²
- Clear backlit LCD display for easy reading
- High resolution readings (0.01 mW/cm²)
- Compact size: 160 × 160 × 42 mm
- Lightweight design (approx. 150g)
- Supplied with 9V (PP3) battery
PAT Test Report Pad (LDM-PR)
- Compliant with IET 5th Edition (2020) requirements
- 40 A4 PAT testing report sheets
- Duplicate NCR (no carbon required) copies for records
- 22 test entries per sheet
- Up to 880 test records per pad
- Suitable for multiple sites and locations
What’s Included
- Kewtech EZYPAT PAT Tester (Battery Operated)
- EZYLEAD Extension Lead Adapter
- EZYEARTH Earth Continuity Test Lead (probe & crocodile clip)
- EZYMAIN Mains Lead
- Carry Bag with Strap
- Quick Start Guide
- Microwave Leakage Detector (LDM-MLD)
- Carry case
- 100 microwave test stickers
- Leaderman PASS Labels – 4 rolls (250 labels per roll)
- Leaderman FAIL Labels – 1 roll (250 labels)
- Leaderman PAT Test Report Pad (LDM-PR)
Click Here – For Full EzyPAT Data Sheet
| Protective Conductor Resistance Test | |
| Measuring Range | 0.00 – 20.00 Ω (NULL value inc)* |
| Over-range Indication | > 20.00 Ω |
| Resolution | 0.01Ω |
| Open-circuit Voltage | 5 V ±0.4 V DC |
| Measuring Current | 200 mA DC (nominal value) |
| Accuracy | ±3%rdg ±5dgt |
| * Resistances exceeding 3 Ω cannot be cancelled by NULL function. | |
| Insulation | |
| Measuring Range | 0.00 – 20.00 MΩ |
| Over-range Indication | > 20.00 MΩ |
| Resolution | 0.01 MΩ |
| No-load Voltage | 250V : 250 V DC 20%, -0% |
| 500V: 500 V DC 20%, -0% | |
| Short-circuit Current | 1.5 mA DC or less |
| Rated Current | 250V: 1 -1.2 mA with a load of 0.25 MΩ |
| 500V: 1 to 1.2 mA with a load of 0.5 MΩ | |
| Accuracy | ±2%rdg±3dgt |
| Substitute Leakage | |
| Measuring Range | 0.10 – 12.00 mA rms |
| Over-range Indication | > 12.00 mA |
| Resolution | 0.01mA |
| Open-circuit Voltage/ Frequency | 30 V ±5 V rms / 50 Hz ±5% |
| Measuring Circuit | 1.2 mA AC ±0.5 mA (when measuring 12.00 mA) |
| Accuracy | ±3%rdg±5dgt |
| Insulation Testy Between L-N | |
| Open-circuit Voltage | 4.5 V ±0.5 V DC |
| Criteria of Judgement | 100 kΩ ±20 kΩ or less: LCD shows “<0.10 MΩ” and the measurement is halted. |
| Physical Specifications | |
| Safety | IEC/EN61010-1 CAT II 300V-instrument IEC/EN61010-2-030 IEC/EN61010-031 CAT III 600V |
| EMC | EN61326-1, 2-2 |
| Possible number of measurements where battery voltage is within the effective range (measuring every 30 sec) | Approx. 1400 times (CLI Rpe: 0 Ω, Rins: 1.1 MΩ) |
| Boxed Weight | 1.61Kg |
| Boxed Dimensions (L x W x D) | 261 x 140 x 130mm |
- Kewtech EZYPAT PAT Tester (Battery Operated)
- EZYLEAD Extension Lead Adapter
- EZYEARTH Earth Continuity Test Lead (probe & crocodile clip)
- EZYMAIN Mains Lead
- Carry Bag with Strap
- Quick Start Guide
- Microwave Leakage Detector (LDM-MLD)
- Carry case
- 100 microwave test stickers
- Leaderman PASS Labels – 4 rolls (250 labels per roll)
- Leaderman FAIL Labels – 1 roll (250 labels)
- Leaderman PAT Test Report Pad (LDM-PR)