Fluke 1736/EUS Three-Phase Power Quality Logger – Gold Edition


Original price was: £3,872.00.£3,432.00Current price is: £3,432.00. / £4,118.40 incl VAT
Discover Our Premium Collection
At Testermans, we take pride in introducing our exclusive range of top-end test equipment. These meticulously curated items transcend the ordinary, offering unparalleled quality and performance. Whether it’s cutting-edge technology, precision measurements, or rugged durability, our limited-stock inventory promises excellence. When marked ‘in stock,’ we dispatch same day with reliable couriers. For backordered products, trust our unbeatable lead times. And don’t forget, our price pledge ensures that you won’t find a better deal elsewhere—like-for-like comparisons included. Plus, every purchase from our premium range comes with a minimum 2-year warranty.
Elevate your experience and order with Testermans today!
In stock
Description


Introducing the Fluke 1736/EUS Three-Phase Power Logger – the ultimate solution for comprehensive energy audits and power quality analysis.
With its advanced measurement capabilities, intuitive software, and rugged design, the Fluke 1736 is the perfect tool for energy consultants, electrical contractors, and industrial maintenance teams who need to identify energy waste, troubleshoot power quality issues, and validate energy efficiency improvements.
This power logger offers unbeatable accuracy, with a measurement range of up to 600V and 6000A, allowing you to capture even the smallest power disturbances. also includes Fluke’s proprietary iFlex flexible current probes, which make it easy to measure large conductors or awkwardly sized cables.
The accompanying Fluke Energy Analyze Plus software provides advanced analysis and reporting features, including automated reporting, customizable dashboards, and an extensive range of export options. With the software, you can easily create detailed reports to share with stakeholders, highlighting energy-saving opportunities and cost-saving measures.
Built to withstand harsh environments, the Fluke 1736 features a rugged design, IP65 rating, and a durable case to protect against accidental drops and damage. It also has a long battery life, enabling you to take measurements for extended periods without interruption.
With the Fluke 1736 Three-Phase Power Logger you can confidently tackle complex energy and power quality projects, reduce energy waste, and optimize energy consumption.
The Fluke 1736 Three-Phase Power Logger also includes a highly valued magnetic probe set at an attractive price.
What’s included:
- Fluke 1736FC/EUS Three-Phase Power Logger
- 4x Fluke 173X-flex1500 iFlexi 1500A Probes (12 inches)
- Fluke MP1-Magnetic Probe Set
- Power Supply
- 4x Voltage Test Leads with Alligator Clips
- Soft Case
- Energy Analysis Plus Software
- Wi-Fi Adapter
- Line Cords
- Colour Coding Set
- USB Containing Instrument Documentation
Please note the Fluke 1736 Three-Phase Power Logger can be upgraded to the Fluke 1738 Three-Phase Power Logger, please contact our sales team for further details.
Fluke 1736/EUS Three-Phase Power Logger Description
The Fluke Connect-enabled Fluke 1736 Three-Phase Power Logger is an entry-level power logger optimised for electrical technicians and contractors, as well as energy saving consultants. It can be used to conduct energy studies and basic power quality logging.
This instrument is capable of automatically capturing and logging over five-hundred power quality parameters; thereby equipping the individual with a comprehensive insight into the relevant data, allowing him/her to make critical power quality and energy decisions in real-time. The Fluke 1736 Three-Phase Power Logger is an effective inspection tool designed for optimising system reliability and savings.
Measurement and Logging
As indicated above the Fluke 1736 Three-Phase Power Logger is supplied with four FREE Fluke 173X-flex1500 iFlexi 1500A Probes (12 inches) which can be used to measure all three power phases and neutral. The Fluke 1736 Three-Phase Power Logger is able to identify and scale each probe. The four current probes are connected separately and can be set to 150A or 1500A, ensuring the best possible accuracy for each application.
The Fluke 1736 Three-Phase Power Logger includes a ‘Verify Connection’ feature to ensure that probes and various test and voltage leads have been connected correctly. The Fluke 1736 Three-Phase Power Logger automatically checks whether probes and leads have been connected correctly and will digitally correct common connection errors without requiring the user to disconnect and reconnect the equipment. Furthermore, the Fluke 1736 Three-Phase Power Logger automatically alerts the user when the wrong current clamp has been connected.
The Fluke 1736 Three-Phase Power Logger’s innovative, tangle-free and flat voltage lead also improves the simplicity and reliability of lead connections.
Once safely connected to the system-under-investigation, the Fluke 1736 Three-Phase Power Logger will record the following parameters simultaneously:
- RMS voltage
- RMS current
- Voltage and current events
- Voltage and current THD
- Voltage and current harmonics up to the 50th harmonic
- Active power
- Reactive power
- Power factor
- Active energy
- Reactive energy
(The above is a small selection of the vast array of critical three-phase power parameters that the Fluke 1736 Three-Phase Power Logger is capable of measuring and logging.)
Measurements are logged automatically, ensuring that data trends are complete; results can be reviewed during logging sessions and/or before they are downloaded for real-time analysis. The Fluke 1736 Three-Phase Power Logger is able to save up to twenty separate logging sessions and has a memory that is large enough to record data acquired over a year.
Downloading, Analysing and Reporting
It is possible to download saved data for further analysis. Measurements may be downloaded to a USB flash drive, which is plugged into the side of the Fluke 1736 Three-Phase Power Logger. Alternatively, the user may view and access data via the Fluke Connect mobile app, allowing him/her to maintain a safer working distance, reducing the need for costly protective equipment.
In addition to maintaining a safer working distance, viewing and sharing measurements with relevant persons via the Fluke Connect App allows teams to make real-time decisions. As a result, task efficiency is increased and the need for further site visits and check-ins is reduced.
Moreover, as the user is able to monitor the Fluke 1736 Three-Phase Power Logger using a Wi-Fi enabled device, he /she can verify its functionality remotely without having to visit the site.
Once downloaded to a PC, data can be charted, graphed and organised into reports using the Fluke Energy Analysis Plus Software. This program is equipped with a suite of powerful analysis tools allowing the user to evaluate every aspect of the energy consumption and power quality state of health. Additionally, this software can be used to create customised reports in PDF and RTF formats quickly and simply.
Easy-to-use, Ergonomic Design
In addition to downloading data for further analysis, the Fluke 1736 Three-Phase Power Logger features a bright, colour, touchscreen display with a graphical indication that can be used to perform in-field analysis and data checks.
Additionally, via the display, front panel and intuitive user interface, the operator can configure (using the quick, guided, graphical setup) the Fluke 1736 Three-Phase Power Logger in order to capture the correct data for each task. Please see the following videos for further information regarding the setup and configuration of this unit.
Alternatively, the Fluke 1736 Three-Phase Power Logger can be configured remotely using the Fluke Connect App. Both configuration methods allow the Fluke 1736 Three-Phase Power Logger to be programmed in the field, adding to the practicality and efficiency of this instrument as it does not need to be returned to a workshop for reprogramming or data download.
Also improving this instrument’s practicality is its ability to be powered from the measured circuit.
Applications
The Fluke 1736 Three-Phase Power Logger’s comprehensive measurement and logging capabilities combined with its easy-to-use and practical design make it suitable for performing the following tasks.
Load Studies
Verify the capacity of an electrical system prior to adding loads.
Energy Assessments
Justify energy-saving measures by quantifying the energy consumption before and after improvements have been made to the circuit.
Harmonic Measurements
Determine issues caused by harmonics that are resulting in damage or disruption to critical equipment.
Voltage and Current Event Capture
Identify dips, swells and inrush currents that are causing false resets or nuisance circuit breaker tripping.
The Fluke 1736 Three-Phase Power Logger is optimised for efficiency, ease-of-use and data visibility. This comprehensive, versatile instrument is the ideal entry-point model for electrical technicians, electrical contractors and energy saving consultants.
Fluke 1736/EUS Three-Phase Power Logger Key Features:
- Measure all three power phases and neutral using the four FREE Fluke 173X-flex1500 iFlexi 1500A Probes (12 inches)
- Identifies and scales each probe
- Probes can be set to 150 A or 1500 A to ensure the best accuracy
- ‘Verify Connection’ feature ensures that probes and test leads have been connected correctly
- The ‘Verify Connection’ feature automatically checks for correct connections and digitally alters common connection errors without disconnecting the measurement leads
- Automatically alerts the user when the wrong current clamp has been connected
- Tangle-free, flat voltage lead for simple and reliable connection
- Simultaneously logs a range of power parameters
- RMS voltage
- RMS current
- Voltage and current events
- Voltage and current THD
- Voltage and current harmonics up to the 50th harmonic
- Active power
- Reactive power
- Power factor
- Active energy
- Reactive energy
- Measurements are logged automatically to ensure data trends are complete
- Review results during logging sessions or before they are downloaded for real-time analysis
- Save up to twenty separate logging sessions
- Capacity to record data acquired over more than a year of logging
- Download data to a USB flash drive
- View and access data via the Fluke Connect App
- Maintain a safer working distance using the Fluke Connect App reducing the need for costly protective equipment
- Share measurements with relevant persons using the Fluke Connect App to facilitate real-time decisions
- Fluke Connect App increases task efficiency and reduces the need for further site visits and check-ins
- Verify the power logger’s functionality remotely via a Wi-Fi device
- Use the Fluke Energy Analysis Plus Software to analyse every detail of the energy consumption and power quality state of health
- Create customised reports using the Fluke Energy Analysis Plus Software
- Bright, colour, touchscreen display with graphical indication
- Perform in-field analysis and data checks via the display
- Configure the logger via the front panel
- User interface with a quick, guided, graphical setup
- Configure the logger remotely using the Fluke Connect App
- No need to remove the Fluke1736 from the field to configure it or download results
- Can be powered from the circuit-under-test
- Suitable for load studies, energy assessment, harmonic measurement and voltage and current event capture applications
- Optimised for efficiency, ease-of-use and data visibility
- A comprehensive and versatile entry-point power logger
Fluke 1736/EUS Three-Phase Power Logger Technical Specifications
| Accuracy | ||||
|---|---|---|---|---|
| Parameter | Range | Max Resolution | Intrinsic Accuracy At Reference Conditions (% of reading + % of full scale) | |
| Voltage | 1000V | 0.1V | ±(0.2% + 0.01%) | |
| Current | i17xx-flex 1500 12″ | 150A 1500A | 0.1A 1A | ±(1% + 0.02%) ±(1% + 0.02%) |
| i17xx-flex 3000 24″ | 300A 3000A | 1A 10A | ±(1% + 0.03%) ±(1% + 0.03%) | |
| i17xx-flex 6000 36″ | 600A 6000A | 1A 10A | ±(1.5% + 0.03%) ±(1.5% + 0.03%) | |
| i40s-EL clamp | 4A 40A | 1mA 10mA | ±(0.7% + 0.02%) ±(0.7% + 0.02%) | |
| Frequency | 42.5Hz to 69Hz | 0.01Hz | ±(0.1%) | |
| Aux Input | ±10V DC | 0.1mV | ±(0.2% + 0.02%) | |
| Voltage Min/Max | 1000V | 0.1V | ±(1% + 0.1%) | |
| Current Min/Max | Defined by accessory | Defined by accessory | ±(5% + 0.2%) | |
| THD On Voltage | 1000% | 0.1% | ±0.5 | |
| THD On Current | 1000% | 0.1% | ±0.5 | |
| Voltage Harmonics – 2nd to 50th | 1000V | 0.1V | ≥10V: ±5% of reading <10V: ±0.5V | |
| Current Harmonics – 2nd to 50th | Defined by accessory | Defined by accessory | ≥3% of current range: ±5% of reading <3% of current range: ±0.1% of range | |
| Unbalance | 100% | 0.1% | ±0.2 | |
| Intrinsic Uncertainty ± (% of reading + % of range)¹ | |||||
|---|---|---|---|---|---|
| Parameter | Influence Quantity | iFlex 1500-12 150A/1500A | iFlex 3000-24 300A/3000A | iFlex 6000-36 600/600A | i40s-EL 4A/40A |
| Active Power Active Energy | PF ≥ 0.99 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
| Apparent Power Apparent Energy | 0 ≤ PF ≤ 1 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
| Reactive Power Reactive Energy | 0 ≤ PF ≤ 1 | 2.5% of measured apparent power | |||
| Power Factor Displacement Power Factor | – | – | ±0.025 | ||
| Additional Uncertainly In % of Range | V P-N > 250V | 0.015% | 0.0225% | 0.0225% | 0.015% |
¹Range = 1000V x Irange
| Electrical Specifications | |
| Power Supply | |
| Voltage Range | 100V to 500V using safety plug input when powering from the measurement circuit |
| 100V to 240V using standard power cord (IEC 60320 C7) | |
| Power Consumption | Maximum 50VA (max 15VA when powered using IEC 60320 input) |
| Efficiency | ≥68.2% (in accordance with energy efficiency regulations) |
| Maximum No-Load Consumption | <0.3W only when powered using IEC 60320 input |
| Mains Power Frequency | 50/60Hz ± 15% |
| Battery | Li-Ion 3.7V, 9.25Wh, customer-replaceable |
| On-Battery Runtime | 4 hours in standard operating mode, up to 5.5 hours in power saving mode |
| Charging Time | <6 hours |
| Data Acquisition | |
| Resolution | 16-bit synchronous sampling |
| Sampling Frequency | 10.24kHz at 50/60Hz, synchronised to mains frequency |
| Input Signal Frequency | 50/60Hz (42.5 to 69Hz) |
| Circuit Types | 1-ϕ, 1-ϕ IT, split phase, 3-ϕ delta, 3-ϕ wye, 3-ϕ wye IT, 3-ϕ wye balanced, 3-ϕ Aron/Blondel (2-element delta), 3-ϕ delta open leg, currents only (load studies) |
| Data Storage | Internal flash memory (not user-replaceable) |
| Memory Size | Typical 10 logging sessions of 8 weeks with 1 minute intervals and 500 events |
| Basic Interval | |
| Measurement Parameters | Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy |
| Averaging Interval | User selectable: 1 sec, 5 sec, 10 sec, 30sec, 1 min, 5 min, 10 min, 15 min, 30 min |
| Averaging Time Min/Max Values | Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms |
| Demand Interval | |
| Measured Parameters | Energy (Wh, varh, VAh), PF, maximum demand, cost of energy |
| Interval | User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off |
| Power Quality Measurements | |
| Measured Parameters | Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD |
| Averaging Interval | 10 min |
| Individual Harmonics | 2nd to 50th |
| Total Harmonic Distortion | Calculated on 50 harmonics |
| Events | Voltage: dips, swells, interruptions Current: inrush current |
| Triggered Recordings | Full cycle RMS updated every half cycle of voltage and current (Urms 1/2 according to IEC61000-4-30) Waveform of voltage and current |
| Standard Compliance | |
| Harmonics | IEC 61000-4-7: Class 1 IEEE 519 (short time harmonics) |
| Power Quality | IEC 61000-4-30 Class S, IEC62586-1 (PQI-S device) |
| Power | IEE 1459 |
| Power Quality Compliance | EN50160 (for measured parameters) |
| Interfaces | |
| USB-A | File transfer via USB flash drive, firmware updates, max. supply current: 120mA |
| WiFI | File transfer and remote control via direct connection or WiFi infrastructure |
| Bluetooth | Read auxiliary measurement data from Fluke Connect 3000 series modules (requires 1738 or 1736 upgrade option) |
| USB-Mini | Data download device to PC |
| Voltage Inputs | |
| Number of Inputs | 4 (3 phases and neutral) |
| Maximum Input Voltage | 1000 Vrms, CF 1.7 |
| Input Impedance | 10MΩ |
| Bandwidth | 42.5Hz to 3.5kHz |
| Scaling | 1:1 and variable |
| Measurement Category | 1000V CAT III/600V CAT IV |
| Current Inputs | |
| Number of Inputs | 4, mode selected automatically for attached sensor |
| Input Voltage | Clamp input: 500mV rms/50mV rms; CF 2.8 |
| Rogowski Coil Input | 150mV rms / 15V mV rms at 50Hz 180mV rms / 18mV rms at 60Hz CF 4 All at nominal probe range |
| Range | 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12” |
| 3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24” | |
| 6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36” | |
| 40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL | |
| Bandwidth | 42.5Hz to 3.5kHz |
| Scaling | 1:1 and variable |
| Auxiliary Inputs | |
| Number of Inputs | 2 |
| Input Range | 0 to ±10V DC, 1 reading/s |
| Scale Factor | Format: mx + b (gain and offset) user configurable |
| Displayed Units | User-configurable (7 characters, for example, °C, psi or m/s) |
| Wireless Connection | |
| Number of Inputs | 2 |
| Supported Modules | Fluke Connect 3000 series |
| Acquisition | 1 reading/s |
| Environmental Specifications | |
|---|---|
| Operating Temperature | -10 to 50°C (14 to 122°F) |
| Storage Temperature | -20 to 60°C (-4 to 140°F With battery: -20 to 50°C (-4 to 122°F) |
| Operating Humidity | 10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH 30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH 40 °C to 50 °C (104 °F to 122 °F) max. 45 % RH |
| Operating Altitude | 2000m (up to 4000m derate to 1000V CAT II/600V CAT III/300V CAT IV |
| Storage Altitude | 12000m |
| Enclosure | IP50 in accordance with EN60529 |
| Vibration | MIL-T-28800E, Type 3, Class III, Style B |
| Safety | IEC 61010-1 IEC Mains Input: Overvoltage Category II, Pollution Degree 2 Voltage Terminals: Overvoltage Category IV, Pollution Degree 2 |
| IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V | |
| Electromagnetic Compatibility (EMC) | EN 61326-1: Industrial CISPR 11: Group 1, Class A |
| Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment) | |
| USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 | |
| Temperature Coefficient | 0.1 x accuracy specification/°C |
| General Specifications | |
| Colour LCD Display | 4.3″ active matrix TFT 480 x 272 pixels Resistive touch panel |
| Warranty | Instrument and power supply: 2 years (battery not included) Accessories: 1 year Calibration Cycle: 2 years |
| Dimensions | Instrument: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in) Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in) Instrument with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in) |
| Weight | Instrument: 1.1 kg (2.5 lb) Power supply: 400 g (0.9 lb) |
| Tamper Protection | Kensington lock slot |
- Fluke 1736/EUS Three-Phase Power Logger
- 4x FREE Fluke 173X-flex1500 iFlexi 1500A Probes (12 inches)
- Fluke MP1-Magnetic Probe Set – Gold Edition ONLY
- Power Supply
- 4x Voltage Test Leads with Alligator Clips
- Soft Case
- Energy Analyse Plus Software
- Wi-Fi Adapter
- Line Cords
- Colour Coding Set
- USB Containing Instrument Documentation
You may also like…
- Sale!
- Data Loggers
Fluke 1738/EUS Advanced Three-Phase Power Quality Analyser Logger
- Original price was: £5,815.00.£5,000.00Current price is: £5,000.00. / £6,000.00 incl VAT
- Add to basket
- Sale!
- Data Loggers
Fluke 1738/B 3-Phase Power Logger, advanced version (no flexis)
- Original price was: £4,955.00.£4,469.00Current price is: £4,469.00. / £5,362.80 incl VAT
- Add to basket