FLUKE 1742/15/EUS – Fluke 1742/EUS Three-Phase Power Quality Logger with 1500A iFlex Probes

Fluke

£4,618.00 / £5,541.60 incl VAT

⚡ Suitable for engineers and technicians requiring a tool to conduct simple load and energy studies
⚡ Able to derive a power source from the circuit-under-investigation
⚡ Supplied with a lithium-ion battery that is able to provide up to four hours of power
⚡ Compact: 23cm x 18cm x 5.4cm
⚡ Analyse every detail of energy consumption and power quality states-of-health using the software

Available on back-order

SKU: FLU-1742/15/EUS Category: Tag: Brand:

Description

FLUKE 1742/15/EUS – Fluke 1742/EUS Three-Phase Power Quality Logger with 1500A iFlex Probes

Product Details:

The Fluke 1742/ EUS Three-Phase Power Quality Logger is suitable for engineers and technicians requiring a tool to conduct simple load and energy studies. This instrument is designed for use in Europe, the UK and the US.

Measurement Functions

The Fluke 1742/ EUS Three-Phase Power Quality Logger is capable of measuring and logging the following power parameters:

  • Voltage
  • Current
  • Power
  • Power Factor
  • Frequency
  • Energy forward/ reverse
  • Peak demand
  • THD
  • Flicker

This diagnostic, inspection and maintenance tool will measure all three voltage and current phases as well as neutral current when used with three-phase and neutral voltage test leads and four flexible current probes (NOT included with the Fluke 1742/B model).

The Fluke 1742/ EUS Three-Phase Power Quality Logger can be placed anywhere on the power installation in order to gather the relevant data for troubleshooting and analysing power distribution systems, and quantifying energy usage. The Fluke 1742/ EUS Three-Phase Power Quality Logger can perform measurements at the service entrance, the substation and the load; it is fully compliant with IEC 61000-4-30 Class A Edition 3 standards and can be used to assess power quality in accordance with EN 50160 and IEEE 519.

Memory and Data Download

The recorded parameters are saved to the Fluke 1742/ EUS Three-Phase Power Quality Logger’s internal memory; it is possible to save in excess of twenty logging sessions to the instrument’s memory. The Fluke 1742/ EUS Three-Phase Power Quality Logger will automatically log a number of parameters in order to ensure that measurement trends are complete.

Saved data can be downloaded to a PC and/or directly to a USB memory stick; it is possible to transfer data to a computer and memory stick simultaneously as the Fluke 1742/ EUS Three-Phase Power Quality Logger is equipped with two USB ports. This allows the user to leave the unit in the field recording measurements directly to a USB drive whilst he/she views the readings remotely from a safer distance via a PC and USB interface.

Alternatively, measurements can be transferred to a PC via an Ethernet connection or Wi-Fi interface. Transferring data via Wi-Fi allows the user to view results remotely, outside of the dangerous area, and in real-time; thereby enabling quick decision-making and reducing the need for PPE.

Analysis and Reporting

The supplied Fluke Energy Analyse Plus Software allows the user to view data that has been transferred to a PC. It also facilitates his/her ability to analyse and create reports from the downloaded data.

At the touch of a button, this software program can be used to create EN 50160, IEEE 519 and GOST 33073 reports. The Fluke Energy Analyse Plus Software’s report templates can be altered in order to accommodate evolving standards.

Alternatively, data can be exported in NeQual and PQDIF formats for use with third-party software. However, the Fluke Energy Analyse Plus Software is equipped with a number of analysis features allowing the user to inspect and evaluate every detail of energy consumption and power quality states-of-health. By selecting a particular parameter, the user can create a customised view thereby facilitating advanced data correlation; additionally, the engineer/ technician can opt to view week/week, day/day or hour/ hour data comparisons.

Ergonomic, Rugged Design

Physical Design

To facilitate multiple methods of data transfer, the Fluke 1742/ EUS Three-Phase Power Quality Logger is equipped with an array of ports, including USB, Ethernet, AUX and I/O. These ports, as well as the instrument’s accessory-connection ports, are all IP65-certified ensuring that they are protected from dust and water ingress when not in use.

In addition to IP65-certification, the Fluke 1742/ EUS Three-Phase Power Quality Logger also has the highest safety rating in the industry (600V CAT IV/ 1000V CAT III), making it suitable for use at service entrances and downstream.

Further to this, the Fluke 1742/ EUS Three-Phase Power Quality Logger has a wide power range and will go from 100V to 500V automatically. This allows it to be powered by the circuit-under-investigation. The unit is also supplied with a lithium-ion battery that can provide up to four hours of power per charge ensuring that it will remain operational in spite of temporary power disruptions to the circuit.

Alternatively, the Fluke 1742/ EUS Three-Phase Power Quality Logger can be powered using a wall line cord.

The small dimensions (23cm x 18cm x 5.4cm) of the Fluke 1742/ EUS Three-Phase Power Quality Logger also improve its practicality: it can be used in tight spaces. The unit may be secured using a standard chain or another security instrument, protecting it from theft and allowing the user to leave the Fluke 1742/ EUS Three-Phase Power Quality Logger safely in the field.

Accessories:

The accessories supplied with the Fluke 1742/ EUS Three-Phase Power Quality Logger match the unit’s resilience and practicality. For instance, the 2m test lead facilitates access to remote conductors.

Similarly, the supplied iFlex current probes (NOT included with the Fluke 1742/B model) also enable access to difficult-to-reach conductors. These IP65-rated probes are thin in design and their wide ranges (probe dependent) ensure a high level of accuracy regardless of the application. These probes are connected separately to the Fluke 1742/ EUS Three-Phase Power Quality Logger ensuring maximum flexibility.

System Interface:

As each probe, clamp or test lead is connected to the Fluke 1742/ EUS Three-Phase Power Quality Logger, the instrument’s intelligent verification feature will check that the accessory has been connected correctly. Incorrect connections are indicated by an amber light that is visible through the power button, this light turns to green when the connections are correct. The intelligent verification feature will automatically correct faulty connections digitally: the user does not need to disconnect or reconnect probes, clamps or test leads.

In addition to this, the Fluke 1742/ EUS Three-Phase Power Quality Logger will automatically recognise, scale and power the connected probes and/or clamps, adding to the reliability, accuracy and ease-of-use of this instrument.

Also adding to the reliability and ease-of-use of this instrument is its graphical, guided, quick PC-application setup interface which ensures that the user is able to configure the Fluke 1742/ EUS Three-Phase Power Quality Logger correctly for each application.

The Fluke 1742/ EUS Three-Phase Power Quality Logger is the entry model in Fluke’s Series of 1740 Power Quality Analysers; nevertheless, this instrument features an eclectic array of measurement features and is optimised for accuracy and ease-of-operation. It is ideal for engineers and technicians performing simple load and energy studies.

Fluke 1742/ EUS Three-Phase Power Quality Logger Key Features

  • Suitable for engineers and technicians requiring a tool to conduct simple load and energy studies
  • Measures and logs a number of power parameters
  • Voltage
  • Current
  • Power
  • Power Factor
  • Frequency
  • Energy forward/ reverse
  • Peak demand
  • THD
  • Flicker
  • Measure all three voltage and current phases as well as neutral current using three-phase and neutral voltage test leads and four iFlex probes (NOT included with the Fluke 1742/B model)
  • Can be placed anywhere along the power installation from the service entrance to the substation to the load
  • Fully compliant with IEC 61000-4-30 Class A Edition 3 Standards
  • Assess power quality in accordance with EN 50160 and IEEE 519 standards
  • Parameters are logged to the unit’s internal memory
  • Capacity to save in excess of twenty logging sessions
  • Automatically records a number of power parameters to ensure measurement trends are complete
  • Download data to a PC via an Ethernet, USB or Wi-Fi connection
  • Download data to a USB stick
  • Two USB ports allow the user to save measurements to a memory stick and transfer results to a PC via a USB interface
  • View data remotely, safely and in real-time via Wi-Fi transfer
  • Use the supplied Fluke Energy Analyse Plus Software to view downloaded data on a PC
  • Create EN 50160, IEEE 519 and GOST 33073 reports using the supplied software
  • The software’s report templates can be altered to accommodate evolving standards
  • Export data in PDQIF and NeQual formats using the Fluke Energy Analyse Plus Software
  • Analyse every detail of energy consumption and power quality states-of-health using the software
  • Select a parameter to create a customised view and thereby facilitate advanced data correlation
  • View day/day, week/week and hour/hour comparisons
  • IP65 ports
  • IP65 body (when used with an IP65 voltage adapter)
  • Highest safety rating in the industry: 600V CAT IV/ 1000V CAT III
  • Suitable for use at service entrances and downstream
  • Wide power range: will go from 100V to 500V automatically
  • Able to derive a power source from the circuit-under-investigation
  • Supplied with a lithium-ion battery that is able to provide up to four hours of power
  • The battery ensures the unit remains operable despite temporary power disruptions
  • Can also be powered using a wall line cord
  • Compact: 23cm x 18cm x 5.4cm
  • Suitable for use in tight spaces
  • Can be protected against theft using a standard chain or another security device
  • 2m test lead provides access to difficult-to-reach conductors
  • The thin, IP65, flexible iFlex current probes (NOT Included with the Fluke 1742/B) also enable access to awkwardly placed conductors
  • The wide ranges of the iFlex probes ensure a high level of accuracy regardless of the application
  • iFlex probes are connected to the unit separately ensuring maximum flexibility
  • Intelligent verification feature ensures that clamps, probes and test leads are connected correctly
  • An amber light indicates incorrect connections
  • A green light indicates correct connections
  • The intelligent verification feature automatically corrects faulty connections digitally
  • Automatically recognises, scales and powers connected probes and clamps
  • Quick, guided, graphical PC-application setup for correct configuration
  • The entry model in Fluke’s 1740 Series of Power Quality Analysers
  • Features an eclectic array of measurement features
  • Optimised for accuracy and ease-of-use
  • Ideal for engineers and technicians performing simple load and energy studies

What’s Included?

  • Your Choice of Fluke 1742/ EUS Three-Phase Power Quality Logger Kit (see below)
ItemsFLUKE1742/15/EUS
Fluke 1742/EUS Three-Phase Power Quality LoggerX
1500A iFlex Current Probes (60cm)X
3000A iFlex Current Probes (60cm)
USB StickX
USB CableX
3PHVL-1730 3-Phase + neutral voltage test leadX
Test lead set red/black 0.18 mX
Test lead set red/black 1.5 mX
Alligator clips4
173x/174x Soft CaseX
Cable marker kitX

 

Fluke 174X Three-Phase Power Quality Loggers Technical Specifications

Please note that the Fluke 1742/EUS Three-Phase Power Quality Loggers are part of Fluke’s range of 174X Three-Phase Power Quality Loggers; the table below details the technical specifications for all the models included in this range.

Specifications
Accuracy
ParameterRangeMaximum ResolutionIntrinsic Accuracy at Reference Conditions (% of Reading +% of Range)
Voltage1000 V0.1 V±0.1 % of nominal voltage 1, 2
Current: Direct inputi17xx-flex 1500IP 24 1500 A150 A0.01 A (min. 1.5A)3±(1% + 0.02%)
1500 A0.1 A
i17xx-flex 3000IP 24 3000 A300 A0.01 A (min. 3.0 A)3±(1% + 0.03%)
3000 A0.1 A
i17xx-flex 6000IP 36 6000 A600 A0.01 A (min. 6.0 A)3±(1.5% + 0.03%)
6000 A0.1 A
i40s-EL clamp4 A1 mA±(0.7% + 0.02%)
40 A10 mA
Frequency42.5 Hz to 69 Hz0.01 Hz±(0.1%)2
Auxiliary input±10 V dc0.1 mV±(0.2% + 0.02%)
Voltage min/max1000 V0.1 V±0.2 % of nominal input voltage1
Current min/maxDefined by accessoryDefined by accessory±(5% + 0.2%)
THD on voltage1000%0.10%± 2.5%
THD on current1000%0.10%± 2.5%
Voltage harmonics 2nd to 50th1000 V0.1 V≥ 1 V: ±5% of reading
< 1 V: ±0.05V
Current harmonics 2nd to 50thDefined by accessoryDefined by accessory≥ 3% of current range: ±5% of reading
< 3% of current range: ±0.15% of range
Flicker PLT, PST0 to 200.015%
Current probe accuracy
ParameterInfluence quantity/iFlex1500IP-24iFlex3000IP-24iFlex6000IP-36i40S-EL
150 A / 1500 A300 A / 3000 A600 A / 6000A4 A / 40 A
Active Power PPF ≥ 0.991.2% + 0.005%1.2% + 0.0075%1.7% + 0.0075%1.2% + 0.005%
Active Energy Ea
Apparent power S0 ≤ PF ≤ 11.2% + 0.005%1.2% + 0.0075%1.7% + 0.0075%1.2% + 0.005%
Apparent Energy Eap
Reactive power Q0 ≤ PF ≤ 12.5% of measured apparent power
Reactive Energy Er
Power Factor PF±0.025
Displacement Power
Factor DPF/cosΦ
Additional uncertainty in% of rangeVP-N>250 V0.015%0.023%0.023%0.015%
1 In the range of 100 V … 500 V; also known as Udin
2 0 °C … 45 °C: Intrinsic accuracy x 2, outside of 0 °C … 45 °C: Intrinsic accuracy x 3
3 Consult operators manual for details
Reference conditions:
Environmental: 23 °C ± 5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65 %
Input conditions: Cosφ/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10 %.
Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V
Input current: I > 10 % of I range
Primary conductor of clamps or Rogowski coil in center position
Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Electrical Specifications
Power Supply
Voltage range100 V to 500 V using safety plug input when powering from the measurement circuit
100 V to 240 V MA-C8 and using standard power cord (IEC 60320 C7)
Power consumptionMaximum 50 VA (max. 15 VA when powered using MA-C8 adapter)
Efficiency≥ 68.2% (in accordance with energy efficiency regulations)
Maximum no-load consumption< 0.3 W only when powered using IEC 60320 input
Mains power frequency50/60 Hz ±15%
BatteryLi-ion 3.7 V, 9.25 Wh, customer-replaceable
On-battery runtimeTypically 4 hours
Charging time< 6 hours
Data Acquisition
Resolution16-bit synchronous sampling
Sampling frequency10.24 kHz at 50/60 Hz, synchronized to mains frequency
Input signal frequency50/60 Hz (42.5 to 69 Hz)
Circuit types1-Φ, 1-Φ IT, split phase, 3-Φ delta, 3-Φ wye, 3-Φwye IT, 3-Φ wye balanced, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, currents only (load studies)
Data storageInternal flash memory (not user replaceable)
Memory sizeTypical 20 logging sessions of 4 weeks with 1-minute intervals and 500 events
Basic Interval
Measured parametersVoltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
Averaging intervalUser selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Averaging time min/max valuesVoltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms)
Demand Interval (Energy Meter Mode)
Measured parametersEnergy (Wh, varh, VAh), PF, maximum demand, cost of energy
IntervalUser selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
Power Quality Measurements
Measured parameterVoltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD, voltage interharmonics, TID V, current interharmonics, TID A, Flicker, Mains Signaling, under/over deviation
Averaging interval10 min for all parameters
2 hrs (long term Flicker PLT)
150/180 cycles (3 s) for harmonics (requires software license IEEE519/REPORT)
Individual harmonics2nd to 50th harmonic
Grouping according to IEC 61000-4-7 user configurable depending on application: Sub-grouped (harmonics + interharmonics), grouped or harmonic bins only
Interharmonics1st to the 50th interharmonic
Total harmonic distortionCalculated on 50 voltage harmonics
EventsVoltage: dips, swells, interruptions, current: inrush current
1748: mains signaling, transients (low frequency)
Triggered recordingsRMS profile: Full cycle RMS updated every half cycle of voltage and current up to 11 s (URMS1/2 according to IEC 61000-4-30)
Waveform of voltage and current up to 200 ms, 10/12 cycles
Mains signaling: 10/12 cycle RMS recording of the configured frequencies up to 120s
InrushRMS profile based on 1/2 cycle RMS steady state triggering
FlickerIn accordance with IEC 61000-4-15 and IEEE 1453
Mains signalingTwo user defined frequencies up to 3 kHz
PQ HealthSummarizes power quality measurements in one table. Detailed data available for each parameter
EN 50160Compliance with standard
Programmable PQ limitsEnables user defined limits for local standards compliance
Standards Compliance
HarmonicsIEC 61000-4-7: Class 1
IEEE 519 (short time and very short time harmonics)
Power qualityIEC 61000-4-30 Class A, IEC 62586-1, IEC 62586-2 (PQI-A-PI device)
PowerIEEE 1459
Power quality complianceEN 50160
SafetyGeneral: IEC 61010-1: Pollution Degree 2
Measurement: IEC 61010-2-033: CAT IV 600 V / CAT III 1000 V
Power Supply: Overvoltage Category IV, Pollution Degree 2
Li-ion Battery: IEC 62133
Interfaces
USB-AFile transfer via USB flash drive, firmware updates, max. supply current: 120 mA
WiFiFile transfer and remote control via direct connection or WiFi infrastructure
BluetoothRead auxiliary measurement data from Fluke Connect® 3000 series modules (requires supported USB to BLE or WiFi/BLE adapter, check for availability)
USB-miniData download device to PC
Current Inputs
Number of inputs4 (3 phases and neutral), mode selected automatically for attached sensor
Input voltageClamp input: 500 mVrms/50 mVrms; CF 2.8
Rogowski coil input: 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4 all at nominal probe range
Range1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 IP 24
3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 IP 24
6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 IP 36
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
Bandwidth42.5 Hz – 3.5 kHz
Scaling1:1 and variable
Auxiliary Inputs
Number of inputs2 (Analog with auxiliary adapter, or up to 2 BLE devices simultaneously)
Input range0 to ± 10 V dc, or 0 to ± 1000 V dc (with optional adapter), 1 reading/s
Scale factorFormat: mx + b (gain and offset) user configurable
Displayed unitsUser configurable (7 characters, for example, °C, psi, or m/s)
Wireless Bluetooth connection (check for availability)
Number of inputs2
Supported modulesFluke Connect® 3000 series
Acquisition1 reading/s
Environmental Specifications
Operating temperature-25 °C to +50 °C (-13 °F to 122 °F)1
Storage temperatureWithout battery: -25 °C to +60 °C (-13 °F to 140 °F), with battery: -20 °C to +50 °C (−4 °F to 122 °F)
Operating humidityIEC 60721-3-3: 3K6:
-25 °C to +30 °C (-13 °F to +86 °F): ≤ 100 %
40 °C (104 °F): 55 %
50 °C (122 °F): 35 %
Operating Altitude2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage altitude12,000 m
EnclosureIEC 60529: IP50
IEC 60529: IP65 with IP65 rated voltage connector
VibrationIEC 60721-3-3 / 3M2
Electromagnetic compatibility (EMC)EN 61326-1: Industrial CISPR 11: Group 1, Class A
IEC 61000-6-5 Power station environment
Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
General Specifications
WarrantyTwo-years (battery not included)
Accessories: one-year
Calibration cycle: two-years
Dimensions23.0 cm x 18.0 cm x 5.4 cm (9.1 in x 7.1 in x 2.1 in)
WeightInstrument: 1 kg (2.2 lb)
Tamper protectionAccept securing cables (max. Φ 6mm)
1Warm up the product to -10 °C (+14 °F) before you power the unit on
Flexible Current Probe Specifications
Specificationsi17XX-FLEX1.5KIPi17XX-FLEX3KIP
Measuring range1 to 150 A ac/10 to 1500 A ac1 to 300 A ac 10 to 3000 A ac
Probe cable length610 mm (24 in)610 mm (24 in)
Probe cable diameter7.5 mm (0.3 in)7.5 mm (0.3 in)
Weight170 g (0.38 lb)170 g (0.38 lb)
Minimum bending radius38 mm (1.5 in)
Nondestructive current100 kA (50/60 Hz)
Temperature coefficient over
operating temperature range
0.05 % of reading/°C (0.028 % of reading/°F)
Working voltage1000 V CAT III, 600 V CAT IV
Output cable length2.0 m (6.5 ft)
Probe cable materialTPR
Weight115 g
Probe cable materialTPR
Coupling materialPOM + ABS/PC
Output cableTPR/PVC
Operating temperature-20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F)
Temperature, non-operating-40 °C to +80 °C (-40 °F to 176

🚚 Testersmans Shipping Policy

Free Mainland GB Delivery Over £150

We offer free delivery on most mainland Great Britain orders over £150 (ex VAT).
This applies across England, Wales, and most of Scotland, excluding certain remote or offshore postcodes.

If your order total falls just short of £150, or you’re a returning customer, feel free to contact us — we may be able to offer a discount code or delivery workaround.
📞 01945 738112 | ✉️ [email protected]


📦 UK Delivery Options

We work with both Royal Mail and DHL to offer reliable and flexible delivery across the UK:

  • Royal Mail – Best suited for lighter parcels and for customers in remote regions, including the Highlands, Islands, and Northern Ireland.
  • DHL – Ideal for most mainland UK orders, providing fast, tracked delivery and excellent reliability for time-sensitive shipments.

Our checkout system automatically displays the available delivery services for your postcode and order weight, ensuring you always see the most suitable options.

Note: Heavy, bulky, or freight-only orders will be charged separately.
Our website is designed for quick, transactional purchases rather than bulk or palletised orders.
Please contact us in advance for a tailored freight quotation if your order falls into this category.


⏱ Dispatch & Delivery Timing

We aim to dispatch all in-stock orders promptly, but delivery depends on both when you order and which service you select.

  • UK orders: placed by 2:00 PM Monday–Friday are usually dispatched the same day.
  • International orders: placed by 2:00 PM Monday–Thursday are usually dispatched the same day.

Orders placed after these times are processed the next working day. This means delivery may occur the following day or later, depending on the courier and service selected.

Once dispatched, your chosen delivery service determines how quickly your parcel arrives:

  • Standard services We use Royal Mail Tracked 24 or DHL Parcel as our ‘Standard’ services. They are not guaranteed to arrive next working day.
  • Premium services (e.g. Royal Mail Special Delivery or DHL by Noon) offer guaranteed delivery windows.

If your order is time-sensitive, we strongly recommend choosing a guaranteed service or contacting us before ordering to confirm availability.

Please note: For logistical reasons, we may occasionally adjust the delivery method selected at checkout. For example, smaller items may be better suited to letterbox-friendly packaging or may be at greater risk of delay or loss via certain services. We actively monitor courier and postal service disruptions—including strikes and delays—and may modify shipping arrangements to help ensure timely and secure delivery.


📅 Busy Periods & Delays

We always aim to dispatch promptly, but delivery times may be affected by:

  • Seasonal demand (e.g. Christmas, bank holidays, or industry shutdowns)
  • Courier network delays outside our control
  • Supplier lead times or calibration requirements for certain equipment

If your delivery is time-critical, please contact us before ordering so we can confirm stock and courier availability.


🌍 International Shipping

We ship worldwide using UPS Express Saver® and other trusted global courier partners. All international shipments are tracked and generally dispatched Monday to Thursday to ensure smooth customs clearance and transit.

Estimated delivery times:

  • Europe: 1–2 working days
  • North America: 2–3 working days
  • Asia-Pacific & Rest of World: 3–5 working days

Delivery times vary depending on location, customs clearance, and local courier performance.


💰 Taxes, Customs & Import Duties

International customers are responsible for any applicable taxes, customs charges, or import duties.
These are not included in our product or shipping prices.

Your courier will typically provide a secure payment link for any import charges once your parcel reaches customs.
If import fees are refused and the parcel is returned, we will issue a refund minus all incurred shipping and return costs.


📍 Using Your Own Courier

If you would prefer to arrange collection via your own courier (UK or international), please contact us before placing your order to coordinate collection from our Wisbech warehouse.


📝 Important Notes

  • Please ensure your delivery address and contact number are correct at checkout.
  • Undelivered parcels may be returned to us after a short holding period.
  • Redelivery or return fees may apply, even if your order originally qualified for free delivery.
  • By placing an order, you confirm your understanding and acceptance of this policy.

Additional information

Weight2000 g