At Testermans, we take pride in introducing our exclusive range of top-end test equipment. These meticulously curated items transcend the ordinary, offering unparalleled quality and performance. Whether it’s cutting-edge technology, precision measurements, or rugged durability, our limited-stock inventory promises excellence. When marked ‘in stock,’ we dispatch same day with reliable couriers. For backordered products, trust our unbeatable lead times. And don’t forget, our price pledge ensures that you won’t find a better deal elsewhere—like-for-like comparisons included. Plus, every purchase from our premium range comes with a minimum 2-year warranty.

Elevate your experience and order with Testermans today!

Price Pledge

Description

Product Details:

The Fluke 1773 Three-Phase Power Quality Analyser is a two-in-one power quality analyser and power quality meter capable of logging data, analysing measurements, and troubleshooting issues. The entry model in Fluke’s 1770 Series of PQAs, the Fluke 1773 Three-Phase Power Quality Analyser, is ideal for energy surveys and load testing, as well as harmonic surveys.

Optimised for simplicity and efficiency, the Fluke 1773 Three-Phase Power Quality Analyser features an easy-to-use interface, a simplified reporting platform, and automatic measurement capture. The streamlined user interface makes it easy to navigate between measurement parameters. As default, the Fluke 1773 Three-Phase Power Quality Analyser captures over five hundred power quality parameters. Its automatic measurement system ensures you collect the right data while allowing you to select and adjust parameters as required.

Harmonics, dips, swells, unbalance, voltage, current, and power, are amongst the five-hundred parameters measured by the Fluke 1773 Three-Phase Power Quality Analyser. Its PQ Meter function provides immediate access to live data, allowing you to identify potential problems quickly while troubleshooting. Data is visible via the Fluke 1773 Three-Phase Power Quality Analysers’ large, bright, touchscreen display.

Additionally, a PQ Logging and Analysis function delivers guided setups making it easy for you to configure the Fluke 1773 Three-Phase Power Quality Analyser. Moreover, guided setups help with selecting the required parameters for the system you are working on and will autocorrect measurement connections digitally meaning you don’t have to change the physical probe connections. Furthermore, the Fluke 1773 Three-Phase Power Quality Analyser supports the creation of custom views allowing you to tailor the PQA to carry out the tests and collect the data relevant to your application.

Data can be transferred to a PC via a USB or OPTIONAL Wi-Fi interface without interrupting the power quality or energy study. Once transferred, the supplied Fluke Energy Analyse Plus Software can be used to view and share results as well as create customised reports. Alternatively, the software’s one-click reporting function can be used to create industry-standard reports (e.g. EN 50160, IEEE 519, and GOST 33073).

Easy-to-use, efficient, and equipped with an eclectic selection of measurement capabilities, the Fluke 1773 Three-Phase Power Quality Analyser is also ergonomic. It can be powered directly from the measurement circuit, removing limitations that come from needing a power outlet or a lengthy extension cord.

The Fluke 1773 Three-Phase Power Quality Analyser is a comprehensive, simple-to-use, and practical test instrument suitable for electrical system troubleshooting and power and energy logging.

 

Key Features:

  • Two-in-one power quality analyser and power quality meter
  • Log data, analyse measurements, and troubleshoot issues
  • Ideal for energy surveys, load testing, and harmonic surveys
  • Easy-to-use interface
  • Simplified reporting platform
  • Automatic measurement capture
  • Streamlined user interface
  • Easily navigate between measurement parameters
  • Captures over 500 power quality parameters
  • Measures harmonics, dips, swells, unbalance, voltage, current, and power
  • PQ Meter function: provides immediate access to live data allowing you to identify potential problems quickly
  • Large, bright touchscreen display
  • Navigation buttons
  • Guided setups for easy configuration and parameter selection
  • Guided setups digitally correct measurement connections
  • Create custom views: tailor the analyser to carry out tests and gather data relevant to your application
  • Data transfer via a USB or OPTIONAL Wi-Fi interface
  • Transfer data without interrupting power quality or energy studies
  • Use the Fluke Energy Analyse Plus Software to view and share results as well as create customised reports
  • One-click reporting function: create industry-standard reports (Fluke Energy Analyse Plus Software)
  • Can be powered directly from the measurement circuit
  • Comprehensive, simple-to-use, and practical test instrument
  • Suitable for electrical system troubleshooting and power and energy logging

 

 

 

What’s Included?

  • Fluke 1773 Three-Phase Power Quality Analyser
  • 4x i17XX-FLEX1500 1500A Current Clamp (2m) (NOT WITH BASIC MODEL)
  • 1x FLUKE-17XX Flat Cable Voltage Test Lead
  • 4x AC285 Black Alligator Clip
  • 1x AC285 Green Alligator Clip
  • 1x USB-C Cable
  • 1x Line Cord
  • 1x FLK-17XX 0.18M Test Lead Set
  • 1x Green Test Lead
  • Cable Marker Set (For Voltage and Current)
  • FLUKE-174X-MA-C8 Wall Outlet Adapter
  • 1x Statement of Calibration Practices

Kit Comparison

FLUKE 1773 FLUKE 1773/BASIC
Fluke 1773 Three-Phase Power Quality Analyser
4x i17XX-FLEX1500 1500A Current Clamp (2m)
1x FLUKE-17XX Flat Cable Voltage Test Lead
4x AC285 Black Alligator Clip
1x AC285 Green Alligator Clip
1x USB-C Cable
1x Line Cord
1x FLK-17XX 0.18M Test Lead Set
1x Green Test Lead
1x Cable Marker Set (For Voltage and Current)
1x FLUKE-174X-MA-C8 Wall Outlet Adapter
1x Statement of Calibration Practices
Statistical Evaluation
 Power quality statistics according to EN50160 and DISDIP tables like ITIC, CEBEMA, ANSI
Event List
 Dips, swells and interruptions are detected and stored in the event list. Also any trigger which fires generates an event added to this list.
 The Event list shows the exact time when the event occurred as well as the duration and magnitude. Sorting by several attributes of these events is possible to select one for further root cause analysis.
 RMS values, transients and fast transients can be stored if a trigger fires.
Continuous Recording
 Fluke 1760 records rms values together with corresponding minimum and maximum values for:
 • Voltage
 • Current
 • Power P, Q, S
 • Power Factor
 • kWh
 • Flicker
 • Unbalance
 • Frequency
 • Harmonics/Interharmonics
 continuously with the following time aggregations:
 Day
 10 min
 Free Interval, e.g.: 15 min, 2h
Triggered Recordings
rms:  Aggregation time is adjustable between 10 ms (1/2 cycle), 20ms (1 cycle), 200ms (10/12 cycles) or 3 sec (150/180 cycles).
 Calculating rms values, Harmonics and Interharmonics is performed synchronous to the power frequency.
 Basic aggregation for harmonics and interharmonics is 200ms
Oscilloscope:  Sample rate is 10.24 kHz for all 8 channels
Fast Transients:  Sample rate is selectable from 100 kHz to 10 MHz for channel 1-4 FFT of Fast Transients
Mains Signalling
 Phases and N-conductor, Voltage and current
Online Mode
 Variable refresh rate. This feature allows verification of instrument set up and delivers a quick overview of oscilloscope, transients and events.

 

General Data
Intrinsic uncertainty
 refers to reference conditions and is guaranteed for two years
Quality system
 developed, manufactured as per ISO 9001: 2000
Environment conditions
Operating temp. range:  0 °C to +50 °C; 32 °F to +122 °F
Working temp. range:  -20 °C to +50 °C; -4 °F to +122 °F
Storage temp. range:  20 °C to +60 °C; -4 °F to 140 °F
Reference temperature:  23 °C ± 2 K; 74 °F ± 2 K
Climatic class:  B2 (IEC 654-1), -20 °C to +50 °C; -4 °F to +122 °F
Max. operating altitude:  2000 m: max. 600 V CAT IV*, power supply: 300 V CAT III 5000 m: max 600 V CAT III*, power supply: 300 V CAT II
* depending on sensor
Reference conditions
Environment temp.:  23 °C ± 2 K ; 74°F ± 2 K
Power supply:  230 V ± 10 %
Power frequency:  50 Hz / 60 Hz
Signal:  declared input voltage Udin
Averaging:  10 minute intervals
Housing
 insulated, robust plastics housing
EMC
Emission:  Class-A as per IEC/EN 61326-1
Immunity:  IEC/EN 61326-1
Power supply
Range:  AC: 83 V to 264 V, 45 to 65 Hz
 DC: 100 V to 375 V
Safety:  IEC/EN 61010-1 2nd edition
 300 V CAT III
Power consumption:  max. 54VA
Battery pack:  NIMH, 7.2 V, 2.7 Ah
 In case of a power supply failure an internal battery maintains the supply for up to 40 minutes. Afterwards, or in case of discharged accumulators the Fluke 1760 is turned off and continues the measurements with the latest settings as soon as the supply voltage returns. The battery can be replaced by the user.
Display
 Fluke 1760 features LED indicators for the status of the 8 channels, phase sequence, power supply (mains or accumulator), memory usage, time synchronization, and data transfer.
Power LED:  • Permanent light: normal power supply from mains.
 • OFF: supply via internal accumulator in case of a power failure.
Channel LEDs  3-color LEDs per channel for:
 • overload condition
 • under load condition
 signal level in nominal range
Data memory
 2 GB Flash memory depending on model
Memory model
 Linear
Interfaces
 Ethernet (100MB/s), compatible to Windows® 98/ME/NT/2000/XP RS 232, external modem via RS 232
Baud rate for RS 232
 9600 Baud to 115 kBaud
Dimensions
 325 mm x 300 m x 65 mm; 2.8 x 11.8 x 2.6 in. (H x W x D)
Weight
 appr. 4.9 kg; 10.8 lbs. (without accessories)
Warranty
 2 years
Calibration interval
 1 year recommended for Class-A, otherwise 2 years

 

Signal Conditioning
Range for 50 Hz systems
 50 Hz ± 15 % (42.5 Hz to 57.5 Hz)
Range for 60 Hz systems
 60 Hz ± 15 % (51 Hz to 69 Hz)
Resolution
 16 ppm
Sampling frequency for 50 Hz power frequency
 10.24 kHz, The sampling rate is synchronized to mains frequency.
Uncertainty for frequency measurements
 < 20 ppm
Uncertainty of internal clock
 < 1s / day
Measurement intervals
 Aggregation of the interval values as per IEC 61000-4-30 Class-A
Min-, Max-values:  Half cycle, e.g.: 10 ms rms values at 50Hz
Transients:  Sample rate 100 kHz to 10 MHz per channel
Harmonics
 as per IEC 61000-4-7:2002: 200 ms
Flicker
 as per EN 61000-4-15:2003: 10 min (Pst), 2 h (Plt)

 

Measurement Inputs
Number of inputs
 8 galvanically isolated inputs for voltage and current measurements.
Sensor safety
 up to 600 V CAT IV depending on sensor
Basic safety
 300 V CAT III
Nominal voltage (rms)
 100 mV
Range (peak value)
 280 mV
Overload capacity (rms)
 1000 V, continuously
Voltage rise rate
 max. 15 kV / µs
Input resistance
 1 MΩ
Input capacitance
 5 pF
Input filter
 Each channel is equipped with a passive low-pass filter, an anti-aliasing filter and a 16-bit A/D converter. All channels are sampled synchronously with a common quartz-controlled clock pulse.
 The filters protect against voltage transients and limit the signal rise rate, reduce high frequency components and especially the noise voltage above half the sampling rate of the A/D converter by 80 dB, thus achieving very small measuring errors in an exceptionally large amplitude range. This is also valid under extreme operating conditions like transient voltages at the output of converters.

 

Uncertainties
Uncertainty at reference conditions
 Uncertainty including the voltage sensors is in compliance with IEC 61000-4-30 Class-A. All voltage sensors are suitable for DC up to 5 kHz
With Sensor 1000 V  0,1% at Udin = 480 V and 600 V P-N
Sensor 600 V  0,1% at Udin = 230 V P-N
Intrinsic uncertainty for harmonics
 Class I as per EN 61000-4-7:2002
Reference conditions
 23 °C ± 2 K < 60 % rH; 74 °F ± 2 K < 60 % rH
 Warmed up instrument > 3h
 Power supply: 100 V to 250 V ac
Temperature drift
 100 ppm / K
Aging
 < 0.05 % / year
Common mode rejection
 > 100 dB at 50 Hz
Temperature drift
 Change of amplification through temperature: < 0.005 %/K
Aging
 Change of amplification due to ageing: < 0.04 %/year
Noise
 Noise voltage, input short-circuited: < 40 µV
DC
 ± (0.2% rdg + 0.1% sensor)