Fluke 355 True RMS 2000 A Clamp Meter

Product Details:

Versatile and rugged clamp meter for high currents

Confidently take reliable readings with the True RMS Fluke 355 digital clamp meter, the tool of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.

  • Easy to use all-in-one tool
  • High voltage measurement of 1000 V AC + DC True RMS, 600 V AC, and 1000 V DC allows the user to perform multiple tests with only one tool
  • Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings

Fluke 355 True RMS 2000 A Clamp Meter Key Features:

  • Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
  • The large 58 mm (2.3 in) jaw capacity is suitable for large, or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows users to perform multiple tests with only one tool (355 only)
  • Resistance to 400 kW coupled with a continuity beeper, provide the convenience of a multimeter (355 only)
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize reading

Specifications: Fluke 355 True RMS 2000 A Clamp Meter

Electrical Specifications
Current measurement DC and AC 10 Hz to 100 Hz Range 40 A / 400 A / 2000 A / 1400 AC rms
Resolution 10 mA / 100 mA / 1 A
Accuracy A: 1.5% rdg + 15 digits
A: 1.5% rdg + 5 digits
Trigger level for Inrush 0.50 A / 5.0 A / 5 A
Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A
Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A
Crest Factor (50/60 Hz) Range 40 A / 400 A / 2000 A / 1400 AC rms
Crest Factor1 2 @ 33 A, 2.4 @ 27 A
2 @ 330 A, 2.4 @ 270 A
2 @ 1000 A, 2.4 @ 833 A
Current measurement AC 100.1 Hz to 1 kHz Range 40 A / 400 A / 2000 A; 1400 AC rms
Resolution 10 mA / 100 mA / 1 A
Accuracy 10 A: 3.5% rdg + 15 digits
10 A: 3.5% rdg + 5 digits
Trigger level for Inrush 0.50 A / 5.0 A / 5 A
Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A
Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A
Voltage measurement DC and AC 10 Hz to 100 Hz
(600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.)
Range 4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC
Resolution 1 mV / 10 mV / 100 mV / 1 V
Accuracy 1% rdg + 10 digits
1% rdg + 5 digits
Trigger level for Hz filter OFF 0.25 V / 6 V
Trigger level for Hz filter ON 0.25 V / 6 V
Voltage measurement AC 100.1 Hz to 1 kHz
(600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.)
Range 4 V / 40 V / 400 V / 600 V ac rms
Resolution 1 mV / 10 mV / 100 mV / 1 V
Accuracy 3% rdg + 10 digits
3% rdg + 5 digits
Trigger level for Hz filter OFF 0.050 V / 0.25 V / 6 V
Trigger level for Hz filter ON 0.050 V / 0.25 V / 6 V
Ohms measurement Range 4 kΩ / 40 kΩ / 400 kΩ
Resolution 0.1 Ω / 1 Ω / 10 Ω / 100 Ω
Accuracy 1.5% + 5 digits
Continuity beeper On at ≤ 30 Ω
Off at ≥ 100 Ω
Frequency measurement Measurement range 5.0 Hz to 1 kHz
Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz 0.2% + 2 counts
Accuracy – 100.1 Hz to 1 kHz 0.5% + 5 counts
Trigger level Refer to current and voltage tables
1. Add 2% to error spec for CF > 2
General Specifications
Batteries Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off) 100 hours
Test leads Rated to 1000 V
Weight .814 kg (1.8 lb)
Jaw size 58 mm (2.28 in)
Dimensions (L x W x D) 300 x 98 x 52 mm (12 x 3.75 x 2 in)
Safety rating IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
Environmental Specifications
Operating temperature 32°F to +122°F (0°C to +50°C)
Storage temperature -4°F to 140°F (-20°C to +60°C)
Operating humidity 0 to 95% (non-condensing)
Operating altitude 2000 m
Storage altitude 10,000 m
IP rating 42 (indoor use only)
Drop test requirements 1 m
EMI, RFI, EMC FCC part 15, IEC/EN 61326-1:1997 class B
IEC/EN 61326:1997 3 V/m, performance criteria B, EN61325
Temperature coefficients Current 0.1% of reading per °C outside 22°C to 24°C
Voltage 0.1% of reading per °C outside 22°C to 24°C

What’s in the box:

  • 355 2000 A Clamp Meter
  • (1 pair) TL224 1.5 m silicone rubber test leads
  • (1 pair) TP2 test probes
  • (1 pair) AC285 alligator clips
  • 6 AA batteries (Installed)
  • C43 soft carrying case
  • Quick Reference Guide
 Zone  Orders Under £75  Orders Over £75
 Zone 1 – UK Mainland Royal Mail 1st Class Delivery (1-2 Days) £5.95
Royal Mail 2nd Class Delivery (3-5 Days) £4.95
DPD Guaranteed Next Day Delivery (Orders must be placed before 2pm) £8.95
Royal Mail 2nd Class Delivery (3-5 Days) FREE
 Zone 2 – Scottish Highlands and Islands Royal Mail 1st Class Delivery (2-3 Days) £5.95
Royal Mail 2nd Class Delivery (5-6 Days) £4.95
DPD Express 2 Day Delivery (Orders must be placed before 2pm) £18.00
Royal Mail 2nd Class Delivery (5 -6 Days) FREE
 Zone 3 – Northern Ireland, Isle of Man, Isles of Scilly Royal Mail 1st Class Delivery (2-3 Days) £5.95
Royal Mail 2nd Class Delivery (5-6 Days) £4.95
DPD Express 2 Day Delivery (Orders must be placed before 2pm) £18.00
Royal Mail 2nd Class Delivery (5 -6 Days) FREE
 Zone 4 – Channel Islands Shipping is dependant on the weight of your order.
Please contact us to complete your order.
 N/A
International Shipping is dependant on the weight of your order and delivery address.
Please complete your order through the checkout or contact us to complete your order.
N/A

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.