Micronics Portaflow PF D650 – Portable Doppler Ultrasonic Flow Meter


£5,335.00 / £6,402.00 incl VAT
⚡ Non-contact measurement – no pipe cutting or flow disruption
⚡ Handles dirty & aerated fluids – perfect for wastewater and slurries
⚡ Wide pipe size compatibility – from 0.5″ to 15 ft
⚡ Long battery life – up to 60 days in sleep-logging mode
⚡ Rugged & portable – IP67 housing, ready for tough environments
⚡ Dispatch 5-10 days
Available on back-order
Description
The Portaflow D650 is a robust, portable non-contact Doppler flow meter designed for fast and accurate measurement of liquids containing suspended solids or entrained gases — even in the harshest industrial environments. Built for versatility and field performance, the D650 enables reliable flow monitoring from outside the pipe, without cutting or interrupting the process.
Housed in a rugged IP67 aluminum enclosure, the D650 delivers exceptional durability, while a high-brightness 2.8” color IPS display provides clear visibility in all conditions. With a massive 12 million point data logger, multiple logging modes including extended sleep-logging, and modern USB-C connectivity, it’s the ideal solution for long-term deployment, field surveys, and challenging flow applications.
🔍 Key Features
Non-contact Doppler measurement – ideal for aerated, dirty, or viscous liquids.
Compatible with fluids containing particles or bubbles (≥100 microns, ≥75 ppm).
Wide pipe size range: from 12.7 mm to 4.6 m (0.5 in to 15 ft) ID.
Intelligent data logging: up to 12 million points with adjustable intervals.
Extended battery life: up to 60 days in sleep-logging mode.
Rugged field design: IP67 aluminum housing, IP68-rated transducer.
Simple setup: clamp-on sensor with stainless steel mounting kit and coupling gel.
Modern interface: 2.8” color display, USB-C data export, and multilingual menu.
Free Windows logger software for data analysis and export.
⚙️ Applications
Sewage and Treated Wastewater
Sludges, Slurries, and Viscous Liquids
Aerated Water and Chemicals
Pulp, Food Products, Abrasives, and Acids
Challenging or contaminated flows where traditional meters fail
🔧 Core Improvements in the D650 over the D550
| Feature | D650 (New) | D550 (Old) | Improvement |
|---|---|---|---|
| Technology Type | Doppler | Transit-Time | Change in measurement principle – Doppler is better for dirty, aerated, or slurry fluids. |
| Suitable Media | Fluids with solids/bubbles (min. 100 microns, 75 ppm) | Clean to moderately dirty liquids | D650 is optimized for harsh/dirty media – a shift in use case. |
| Data Logging Capacity | 12 million points | Typically much lower (~98k points in many portable flowmeters) | Massive increase in logging capacity. Great for long-term deployments. |
| Display | 2.8” Color TFT IPS LCD, 320×240, 500 NITS | Likely monochrome or basic LCD | Big upgrade in screen visibility and user experience. |
| Battery Life | Up to 15 hrs (or 60 days in low-power sleep-logging mode) | ~12–14 hrs typical | More flexible power management + long-term unattended deployment. |
| Enclosure | IP67 extruded aluminum + IP65/IP67 rated electronics | Often IP54/IP65 plastic | D650 is ruggedized for industrial/field conditions. |
| Logging Modes | Standard + Sleep-Logging | Typically only standard logging | Better for remote or infrequent access setups. |
| Data Output | USB-C flash drive support with direct CSV/log file export | Often serial/USB with custom software | Faster and simpler data access. Modern I/O. |
| Software | Free Logger Software (Windows), CSV support | Usually required proprietary tools | Improved data accessibility and portability. |
| Sensor Spec | Clamp-on Doppler sensor, IP68 rated, -40°C to +150°C | Transit-time sensors, less tolerant to high temp | Wider environmental range and better ingress protection. |
| Accuracy | ±2% or 0.03 m/s | ±1% to ±2% (D550) | Accuracy is similar, but D650 handles more difficult flow. |
| Pipe Size Range | 0.5″ to 15 ft | ~0.5″ to 78″ (depends on D550 model) | Range is comparable, but D650 likely handles larger industrial pipes better. |
🎯 Key Takeaways
✅ Target Application Shift: The D650 is focused on tougher applications — sewage, slurries, viscous/chemical media — thanks to the Doppler principle.
✅ Rugged & Portable: Built for harsh field work, with better protection (IP67/68), a carry case, and longer battery life.
✅ Modernized User Experience: USB-C, high-brightness color screen, intuitive interface, and simple data access/export — all big quality-of-life upgrades.
✅ Massive Data Logging: 12 million data points with configurable intervals and sleep mode — ideal for unattended long-term monitoring.
🤔 So, Should You Upgrade?
If your work involves:
Fluids with suspended solids, bubbles, or aerated/slurry content,
Demands portable, rugged performance in the field,
Requires long logging durations or modern data handling…
Then yes — the Portaflow D650 offers substantial improvements over the D550!
| Operating Parameters | Liquids containing suspended solids or bubbles minimum size of 100 microns, minimum concentration 75 ppm | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Flow Rate Range | ±0.03 m/s to 12.2 m/s (±0.1 ft/s to 40 ft/s) in most applications | ||||||||||||||
| Pipe Size | Ultrasonic sensor mounts on any pipe from 12.7 mm to 4.6 m ID (0.5 in to 15 ft) | ||||||||||||||
| Display | Colour TFT LCD, IPS type, 2.8” screen size, 320 x 240 resolution, 500 NITS brightness, super wide view | ||||||||||||||
| Power Input | Built-in rechargeable lithium polymer battery for up to 15 hours of continuous operation External mains to USB-C charger with 100-240V AC, 50-60Hz, 0.6A input; and 5.0V DC, 3A, 15W output | ||||||||||||||
| Outputs | Log files, daily log files, parameter settings files, and waveform capture files via USB-C flash drive (included) | ||||||||||||||
| Data Logger | 12 million point capacity, configurable for velocity or flow rate, date and time stamped, configurable format for Logger Software (LG2) or CSV, available intervals of 10 s, 30 s, 1 min, 2 min, 5 min, 10 min, 15 min, 30 min, and 1 hr | ||||||||||||||
| Extended Logging | Can be deployed in sleep-logging mode for extended battery duration.
| ||||||||||||||
| PC Software | Free Logger Software for Windows. For display, manipulation, analysis, and exporting of data. | ||||||||||||||
| Operating Temperature (Electronics) | -20 °C to +60 °C (-5 °F to +140 °F) | ||||||||||||||
| Electronics Enclosure | IP67 when transducer cables are connected. IP65 when transducer cables are not connected. Aluminium enclosure with silicone protective end covers. | ||||||||||||||
| Carry Case | IP67, with protective moulded foam with room for transducer and installation hardware | ||||||||||||||
| Accuracy | ±2% of reading or 0.03 m/s (0.1 ft/s), whichever is greater. Requires solids or bubbles minimum size of 100 microns, minimum concentration of 75 ppm. Repeatability: ±0.1%, Linearity ±0.5% | ||||||||||||||
| Configuration | Built-in 5-button keypad interface with English, French, and Spanish menu language selection. Optional user-configured password protection. | ||||||||||||||
| Approvals | CE | ||||||||||||||
| Transducer Specifications | |||||||||||||||
| Standard Model PSE4-A2 | Clamp-on, single-head ultrasonic for pipes from 12.7 mm to 4.6 m ID (0.5 in to 15 ft) with 3.4 m (12 ft) shielded dual-coaxial cable and latching connector | ||||||||||||||
| Sensor Mounting Kit | Stainless steel pipe clamp and 3.0 fl oz coupling compound | ||||||||||||||
| Stainless steel pipe clamp and 3.0 fl oz coupling compound | Steel, stainless steel, cast iron, ductile iron, concrete-lined ductile iron, PVC, HDPE, or any contiguous pipe material that conducts sound, including lined pipes with a liner bonded to the pipe wall. Avoid pipes with loose insertion liners and pipe walls that contain air. | ||||||||||||||
| Operating Temperature | -40 °C to +150 °C (-40 °F to +300 °F) | ||||||||||||||
| Ingress Protection | IP68, can withstand 10psi (approx. 23 ft or 7 m of H2O) for 24 hours | ||||||||||||||
What’s Included?
- PF D650 Electronics
- Transducer cable
- USB-C Wall Charger
- SE14-A2 Transducer Mounting Bracket
- Coupling Compound, 3 oz Super Lube
- SE14-A2 Transducer w/ Cable
- Two Hose Clamps
- International Plug Adapters for USB-C Wall Charger