Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit with 9040 Phase Rotation Meter & i400 AC Current Clamp

Fluke

£893.00 / £1,071.60 incl VAT

⚡ Utilise the Fluke 1587 FC for insulation tests and a range of digital multimeter functions

⚡ Measure AC current without breaking the circuit, with the Fluke i400 and Fluke 1587 FC

⚡ Inspect the rotation of three-phase motors using the versatile Fluke 9040

Available on back-order

Price Pledge
SKU: FLU-1587/MDT Category: Tags: , Brand:

Description

Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit with 9040 Phase Rotation Meter & i400 Current Clamp

The Fluke 1587 FC Insulation Multimeter features four powerful new diagnostic functions through the Fluke Connect Measurements app:

  • Pl/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster
  • Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
  • Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
  • Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets

The Fluke i400 AC Current Clamp (400A)  is a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, helping you take measurements safely with industry standard safety ratings.

Fluke 9040 Phase Rotation Indicator is effective for measuring phase rotation in all areas where three phase supplies are used to feed motors, drives and electrical systems. It allows rapid determination of phase sequence and ideally suited for commercial and industrial applications.

Key features

Includes a Fluke 1587 FC 2-in-1 Insulation DMM, Fluke i400 Current Clamp, and a Fluke 9040 Phase Rotation Indicator

  • With the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease
  • Use the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuit
  • Check the rotation of three-phase motors easily and safely with the Fluke 9040

The Fluke 1587 FC 2-in-1 Insulation Multimeter

  • Pl/DAR measurements with TrendIt™ graphs
  • Memory storage through Fluke Connect Measurements app
  • Temperature Compensation through Fluke Connect Measurements app
  • VFD low-pass filter for accurate motor drive measurements
  • Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
  • Insulation test voltages 500 V, 1000 V
  • Insulation test: 0.01 MΩ to 2.0 GΩ
  • Insulation test: 0.1 MΩ to 600 MΩ
  • Auto-discharge of capacitive voltage
  • Insulation test smoothing reading
  • Frequency / Capacitance / Diode test / Temperature
  • Min/Max / AC/DC Voltage / DC Millivolts / AC/DC Milliamps
  • Resistance (0.1 Ω to 50 MΩ) / Continuity / Auto power off
  • Three-year warranty
  • Remote probe, test leads, alligator clips,
  • K-type thermocouple
  • Large Soft Carry Case

Fluke i400 AC Current Clamp

  • Use with your Fluke 1587 FC to measure 1A AC to 400 A AC
  • 1 mA/Amp output guarantees easy reading
  • CAT III 1000 V / CAT IV 600 V overvoltage rating for added user protection
  • Specially designed to offer maximum utility in a very compact shape
  • Maximum conductor: Ø 32 mm
  • 1 year warranty

Fluke 9040 Phase Rotation Indicator

  • Large display to easily determine field rotation and phase sequence
  • Indication for all three phases
  • CAT III 600 V overvoltage rating
  • 2 year warranty

What’s Included:

  • Fluke 1587 FC Insulation Tester/Digital Multimeter
  • Fluke i400 Current Clamp
  • Fluke 9040 Phase Rotation Indicator
  • Remote Probe
  • 1587 Test Leads Probes and Croc Clips
  • Probes/Croc Clips for Phase Rotation Indicator
  • Large Soft Carrying Case

Fluke 1587 FC Insulation Multimeter

Electrical Specifications
AC voltage measurement
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
¹ 1 kHz bandwidth
Low-Pass Filter Voltage
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
DC Voltage Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
6.000 V dc 0.001 V ±(0.09% + 2)
60.00 V dc 0.01 V ±(0.09% + 2)
600.0 V dc 0.1 V ±(0.09% + 2)
1000 V dc 1 V ±(0.09% + 2)
Input impedance 10 MΩ (nominal), <100 pF
Normal mode rejection ratio >60 dB @ 50 Hz or 60 Hz
Common mode rejection ratio >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
Accuracies apply to ± 100% of range
DC Millivolts Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
600.0 mVdc 0.1 mV ±(0.1% + 1)
DC and AC Current Measurement
AC 45 Hz to 1000 Hz
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
DC
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Overload 600 mA for 2 minutes maximum
Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA
AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input
Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
¹ 1 kHz bandwidth
Ohms Measurement
Range Resolution Accuracy +(% of Rdg+Counts)¹
600.0 Ω 0.1 Ω ±(0.9% + 2)
6.000 kΩ 0.001 kΩ ±(0.9% + 2)
60.00 kΩ 0.01 kΩ ±(0.9% + 2)
600.0 kΩ 0.1 KΩ ±(0.9% + 2)
6.000 MΩ 0.001 MΩ ±(0.9% + 2)
50.0 MΩ ² 0.01 MΩ ±(1.5% + 3)
Overload protection 1000 V rms or dc
Open circuit test voltage <8.0 V dc
Short circuit current <1.1 mA
¹ Accuracies apply from 0% to 100% of range
² Up to 80% relative humidity
Diode Test
Diode test indication Display voltage drop: 0.6 V at1.0 mA nominal test current:
Accuracy ±(2% + 3)
Continuity Test
Continuity indication Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω
Open circuit voltage <8.0 V
Short circuit current 1.0 mA typical
Overload protection 1000 V rms
Response time >1 m sec
Frequency Measurement
Range Resolution Accuracy ±(% of Rdg+Counts)
99.99 Hz 0.01 Hz ±(0.1% + 1)
999.9 Hz 0.1 Hz ±(0.1% + 1)
9.999 kHz 0.001 kHz ±(0.1% + 1)
99.99 kHz 0.01 kHz ±(0.1% + 1)
Frequency Counter Sensitivity
600.0 mV ac V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 100.0 mV
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 150.0 mV
DC Trigger Levels¹ to 20 kHz² NA
6.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 1.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 1.5 V
DC Trigger Levels¹ to 20 kHz² -400.0 mV and 2.5 V
60.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 10.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 36.0 V
DC Trigger Levels¹ to 20 kHz² 1.2 V and 4.0 V
600.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 100.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
1000.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 300.0 V
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
² Usable to 100 kHz with full scale input
Capacitance
Range Resolution Accuracy ±(% of Rdg+Counts)
1000 nF 1 nF ±(1.2% + 2)
10.00 μF 0.01 μF ±(1.2% + 2)
100.0 μF 0.1 μF ±(1.2% ±90 counts)
9999 μF 1 μF ±(1.2% ±90 counts)
Temperature Measurement
Range Resolution Accuracy ±(% of Rdg+Counts)¹
-40 ° C to 537 ° C 0.1 °C ±(1% + 10 counts)
-40 ° F to 998 ° F 0.1 °F ±(1% + 18 counts)
¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument
Insulation Specifications
Measurement range 0.01 MΩ to 2 GΩ
Test voltages 50, 100, 250, 500, 1000 V
Test voltage accuracy +20%, -0%
Short-circuit test current 1 mA nominal
Auto discharge Discharge time <0.5 second for C = 1 μF or less
Live circuit detection Inhibit test if terminal voltage > 30 V prior to initialization of test
Maximum capacitive load Operable with up to 1 μF load
Output Voltage
50 V (0% to +20%) Display range 0.01 to 6.00 MΩ
Resolution 0.01 MΩ
Test current 1 mA @ 50 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 50.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 50 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
100 V (0% to +20%) Display range 0.01 to 6.00 MΩ
Resolution 0.01 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 60 to 100 MΩ
Resolution 1 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
250 V (0% to +20%) Display range 0.1 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 250 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 250 MΩ
Resolution 1 MΩ
Test current 1 mA @ 250 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
500 V (0% to +20%) Display range 0.1 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 500 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 500 MΩ
Resolution 1 MΩ
Test current 1 mA @ 500 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
1000 V (0% to +20%) Display range 0.1 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 600 MΩ
Resolution 1 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 0.6 to 2.0 GΩ
Resolution 100 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(10% + 3 counts)
General Specifications
Maximum voltage applied to any terminal and common 1000 V
Storage temperature -40 °C to 60 °C (-40 °F to 140 °F)
Operating temperature -20 °C to 55 °C (-4 °F to 131 °F)
Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
Relative humidity Noncondensing
0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)
0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)
0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)
Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Radio frequency communication 2.4 GHz ISM Band
Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE
Electromagnetic Compatibility
International IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Enclosure protection IEC 60529: IP40 (non-operating)
Safety
IEC 61010-1 Pollution Degree 2
IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V
Batteries Four AA batteries (NEDA 15A or IEC LR6)
Battery life Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Size (H x W x L) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
Weight 550 g (1.2 lb)
Altitude Operating 2000 m
Storage 12,000 m
Over-range capability 110% of range except for capacitance which is 100%
Frequency overload protection <107 V Hz
Fuse protection for mA input 0.44A, 1000 V, IR 10 kA

Fluke i400 AC Current Clamp

Specifications
Nominal current range 400  A
Continuous current range 1 A – 400 A
Maximum non-destructive current 1000 A
Lowest measurable current 1 A
Basic accuracy 2% + 0.06 A
(45-400 Hz)
(% reading + floorspec)
Useable frequency 5 Hz – 20 kHz
Output level(s) 1 mA/A
Safety Specifications
Safety CAT IV 600 V, CAT III, 1000 V
Maximum voltage 1000 V AC rms from earth to ground, in compliance with EN61010
Mechanical and General Specifications
Warranty 1 year
Maximum conductor diameter 32 mm (1.25 in)
Maximum conductor size (busbar) 750 MCM
Output cable length 1.5 m (59 in)
Shrouded banana plugs Yes

Fluke 9040 Phase Rotation Indicator

Technical Specifications
Voltage range 40-700 V
Frequency range 15-400 Hz
Operating timer Continuous
Environmental Specifications
Operating temperature 0 °C to 40 °C
Dust/water resistance IP 40
Safety Specifications
Electrical safety EN 61010,  EN 61557-7
Overvoltage category CAT III, 600 V
CAT IV, 300V
Mechanical and General Specifications
Size 124 x 61 x 27 mm
Weight 200 g
Power supply From unit under test
Warranty 2 years

What’s Included:

  • Fluke 1587 FC Insulation Tester/Digital Multimeter
  • Fluke i400 Current Clamp
  • Fluke 9040 Phase Rotation Indicator
  • Remote Probe
  • 1587 Test Leads Probes and Croc Clips
  • Probes/Croc Clips for Phase Rotation Indicator
  • Large Soft Carrying Case

🚚 Testersmans Shipping Policy

Free Mainland GB Delivery Over £150

We offer free delivery on most mainland Great Britain orders over £150 (ex VAT).
This applies across England, Wales, and most of Scotland, excluding certain remote or offshore postcodes.

If your order total falls just short of £150, or you’re a returning customer, feel free to contact us — we may be able to offer a discount code or delivery workaround.
📞 01945 738112 | ✉️ sales@testermans.co.uk


📦 UK Delivery Options

We work with both Royal Mail and DHL to offer reliable and flexible delivery across the UK:

  • Royal Mail – Best suited for lighter parcels and for customers in remote regions, including the Highlands, Islands, and Northern Ireland.
  • DHL – Ideal for most mainland UK orders, providing fast, tracked delivery and excellent reliability for time-sensitive shipments.

Our checkout system automatically displays the available delivery services for your postcode and order weight, ensuring you always see the most suitable options.

Note: Heavy, bulky, or freight-only orders will be charged separately.
Our website is designed for quick, transactional purchases rather than bulk or palletised orders.
Please contact us in advance for a tailored freight quotation if your order falls into this category.


⏱ Dispatch & Delivery Timing

We aim to dispatch all in-stock orders promptly, but delivery depends on both when you order and which service you select.

  • UK orders: placed by 2:00 PM Monday–Friday are usually dispatched the same day.
  • International orders: placed by 2:00 PM Monday–Thursday are usually dispatched the same day.

Orders placed after these times are processed the next working day. This means delivery may occur the following day or later, depending on the courier and service selected.

Once dispatched, your chosen delivery service determines how quickly your parcel arrives:

  • Standard services We use Royal Mail Tracked 24 or DHL Parcel as our ‘Standard’ services. They are not guaranteed to arrive next working day.
  • Premium services (e.g. Royal Mail Special Delivery or DHL by Noon) offer guaranteed delivery windows.

If your order is time-sensitive, we strongly recommend choosing a guaranteed service or contacting us before ordering to confirm availability.

Please note: For logistical reasons, we may occasionally adjust the delivery method selected at checkout. For example, smaller items may be better suited to letterbox-friendly packaging or may be at greater risk of delay or loss via certain services. We actively monitor courier and postal service disruptions—including strikes and delays—and may modify shipping arrangements to help ensure timely and secure delivery.


📅 Busy Periods & Delays

We always aim to dispatch promptly, but delivery times may be affected by:

  • Seasonal demand (e.g. Christmas, bank holidays, or industry shutdowns)
  • Courier network delays outside our control
  • Supplier lead times or calibration requirements for certain equipment

If your delivery is time-critical, please contact us before ordering so we can confirm stock and courier availability.


🌍 International Shipping

We ship worldwide using UPS Express Saver® and other trusted global courier partners. All international shipments are tracked and generally dispatched Monday to Thursday to ensure smooth customs clearance and transit.

Estimated delivery times:

  • Europe: 1–2 working days
  • North America: 2–3 working days
  • Asia-Pacific & Rest of World: 3–5 working days

Delivery times vary depending on location, customs clearance, and local courier performance.


💰 Taxes, Customs & Import Duties

International customers are responsible for any applicable taxes, customs charges, or import duties.
These are not included in our product or shipping prices.

Your courier will typically provide a secure payment link for any import charges once your parcel reaches customs.
If import fees are refused and the parcel is returned, we will issue a refund minus all incurred shipping and return costs.


📍 Using Your Own Courier

If you would prefer to arrange collection via your own courier (UK or international), please contact us before placing your order to coordinate collection from our Wisbech warehouse.


📝 Important Notes

  • Please ensure your delivery address and contact number are correct at checkout.
  • Undelivered parcels may be returned to us after a short holding period.
  • Redelivery or return fees may apply, even if your order originally qualified for free delivery.
  • By placing an order, you confirm your understanding and acceptance of this policy.

You may also like…