Fluke 1674FC and FEV300/Type 2 EV Electric Vehicle Charging Station Test Simulator Kit with Type2 Adaptor

Fluke

£2,448.00 / £2,937.60 incl VAT

Fast & Efficient Testing: Auto Test speeds up installations by 30%, with instant pass/fail indicators.

EV Charging Station Ready: Includes FEV300 adapter for compliant Mode 3 EVSE testing.

Enhanced Safety: Insulation PreTest™ prevents accidental equipment damage during tests.

Seamless Data Management: Fluke Connect™ and TruTest™ software enable easy reporting and wireless syncing.

Comprehensive Functionality: RCD, SPD, loop impedance, and motor winding tests in one robust, portable kit.

Only 1 left in stock

SKU: FLU-1674FC/FEV300 Category: Tag: Brand:

Description

Fluke 1674FC Multifunction Tester & FEV300 Type 2 EV Charging Station Test Simulator Kit

Overview

The Fluke 1674FC Multifunction Tester, paired with the FEV300 Type 2 EV Charging Station Test Simulator Kit, delivers unmatched precision, speed, and safety for testing environments. Designed for domestic, commercial, and industrial applications, this comprehensive kit ensures you stay compliant with industry standards like IEC/HD 60364-6 and IEC/EN 61851-1. Whether testing electrical installations or maintaining EV charging stations, this powerful duo simplifies testing while enhancing productivity.


Fluke 1674FC Multifunction Tester

Advanced Features for Faster, Safer Testing

  • Full-Color Touchscreen & Rotary Dial: Effortlessly navigate test settings for quick and accurate results.
  • Auto Test Functionality: Complete installation test sequences with a single button press—reducing setup time and speeding testing by up to 30%.
  • Patented Insulation PreTest™: Protect connected equipment with automatic testing safeguards that detect and alert operators to unsafe conditions.
  • High Precision: Perform loop and line impedance measurements with milliohm (mΩ) resolution.

Exceptional Versatility

The 1674FC supports comprehensive tests, including:

  • Insulation Monitoring Device (IMD) and Surge Protection Device (SPD) functionality.
  • RCD testing (AC, A, F, B, and B+ types) with trip time and current measurements in a single test.
  • Z-max memory for analyzing peak loop test values.
  • Low-current continuity tests ideal for motor winding measurements.

Optimized User Experience

  • Streamlined Test Setup: Organize testing environments with customizable structures for clients, sites, and test points—directly on the tester or via a PC/smart device.
  • Fluke Connect™ Integration: Sync, customize, and edit data wirelessly for seamless reporting and troubleshooting.
  • TruTest™ Software Compatibility: Create professional, industry-standard reports effortlessly, complete with company branding.

Built for Rugged Efficiency

  • Rechargeable lithium-ion battery with USB-C charging for all-day performance.
  • Safety-rated CAT III 600V / CAT IV 300V with raised voltage detection for high-risk environments.
  • Compact, lightweight design with a neck strap and hard case for portability and protection.

Fluke FEV300 Type 2 EV Charging Station Test Simulator Kit

Essential for EV Charging Station Testing

Designed to test AC charging stations (Mode 3) in compliance with IEC/EN 61851-1 and IEC/HD 60364-7-722, the FEV300 adapter eliminates the need for an electric vehicle onsite. Its intuitive controls simulate various charging states and faults for thorough maintenance and troubleshooting.

Key Features

  • Proximity & Control Pilot Simulations: Replicate charging cable and vehicle states to verify station performance.
  • Error Simulation: Test CP (E) and PE (earth fault) errors with ease.
  • Phase Indication: LED lamps clearly display phase voltage status for safe and efficient testing.

Simplicity Meets Versatility

  • Conduct ground fault checks, insulation testing, and voltage/duty cycle measurements all in one tool.
  • Seamlessly integrates with the Fluke 1674FC and other Fluke instruments for a unified testing experience.

What’s Included

Fluke 1674FC Multifunction Tester

  • Heavy-duty mains cord with single input connector.
  • Remote control probe, hanging strap, and zero adapter.
  • Test leads, probes, and alligator clips.
  • USB-C charger and Li-ion battery.
  • Hard carrying case.

Fluke FEV300 Type 2 EV Test Simulator Kit

  • FEV300 Test Adapter with Type 2 Plug.
  • Carrying case.
  • Fluke’s 3-Year Warranty.

Upgrade your testing toolkit with the Fluke 1674FC and FEV300 Kit—delivering unmatched precision, efficiency, and safety for modern testing challenges.

Specifications: 

  • Size: 26.25cm x 14.19cm x 11.93cm (10.3 x 5.6 x 4.7in)
  • Weight (including batteries)1.6KG (3.5lb)
  • Battery size, quantity: B290, Li-ion, 10.8V, 2500 mAH, 27 Wh
  • Ingress Protection: IEC 60529; IP40
  • Safety: Complies with IEC/EN 61010-1, IEC 61010-2-030, IEC 61010-2-034
  • Safety rating: CAT III 600 V, CAT IV 300 V
  • Performance: IEC 61557-1 to IEC/EN 61557-8 and IEC 61557-10

Voltage measurement AC, DC and Frequency

  • Range: 600V
    Resolution: 0.1V
    Input Impedance: 320 kΩ
    Overload Protection: 660V
  • Range: 45-66Hz
    Resolution: 0.1Hz
    Input Impedance: 320 kΩ

Continuity testing (RLO)

  • Range (Auto ranging): 20Ω/200Ω/2000Ω
    Resolution: 0.01 Ω/0.1 Ω/1 Ω
    Open Circuit Voltage: >4V

Insulation Resistance measurement (Riso)

  • Test Voltages: 50-100-250-500-1000V
  • 50V:
    Insulation Resistance Range: 10 kΩ to 50 MΩ
    Resolution: 0.01 MΩ
    Test Current: 1 mA @ 50 kΩ
  • 100V:
    Insulation Resistance Range: 10 kΩ to 20 MΩ
    Resolution: 0.01 MΩ
    Test Current: 1 mA @ 100 kΩ
  • 100V:
    Insulation Resistance Range: 20 kΩ to 100 MΩ
    Resolution: 0.1 MΩ
    Test Current: 1 mA @ 100 kΩ
  • 250V:
    Insulation Resistance Range: 10 kΩ to 20 MΩ
    Resolution: 0.01 MΩ
    Test Current: 1 mA @ 250 kΩ
  • 250V:
    Insulation Resistance Range: 20 kΩ to 200 MΩ
    Resolution: 0.1 MΩ
    Test Current: 1 mA @ 250 kΩ
  • 500V:
    Insulation Resistance Range: 10 kΩ to 20 MΩ
    Resolution: 0.01 MΩ
    Test Current: 1 mA @ 500 kΩ
  • 500V:
    Insulation Resistance Range: 20 kΩ to 200 MΩ
    Resolution: 0.1 MΩ
    Test Current: 1 mA @ 500 kΩ
  • 500V:
    Insulation Resistance Range: 200 kΩ to 500 MΩ
    Resolution: 1 MΩ
    Test Current: 1 mA @ 500 kΩ
  • 1000V:
    Insulation Resistance Range: 100 kΩ to 200 MΩ
    Resolution: 0.1 MΩ
    Test Current: 1 mA @ 1MΩ
  • 1000V:
    Insulation Resistance Range: 200 kΩ to 1000 MΩ
    Resolution: 1 MΩ
    Test Current: 1 mA @ 1MΩ

Insulation pretest

  • Insulation Safety pretest: Connections from the tester to L, N and PE are required

Surge Protection Device (SPD) Insulation RAMP Test (Varistor Test) IEC 61643-11

  • Test Voltage: 500V:
    Voltage ranges: Step Ramp 0V to 500V
    Resolution: 1V
    Test Current: 1mA
    Accuracy: ± (1.5 % + 3 digits)
  • Test Voltage: 1000V:
    Voltage ranges: Step Ramp 0V to 1000V
    Resolution: 1V
    Test Current: 1mA
    Accuracy: ± (1.5 % + 3 digits)

Insulation Monitoring Devices (IMD) IEC 61557-8

  • Range: 1 kΩ to 10 kΩ
    Resolution: 1 kΩ
  • Range: 10 kΩ to 100 kΩ
    Resolution: 10 kΩ
  • Range: 100 kΩ to 3 mΩ
    Resolution: 100 kΩ
  • Please note: > 1 MΩ only available with voltages >100 V

Loop and line impedance (ZI No Trip and Hi Current)

  • Range setting: 10 Ω
    Resolution: 0.001 Ω
    Accuracy: Hi Current mΩ mode: ± (2 % + 35 digits)/No Trip (2&3 wire) mode: ± (3 % + 6 digits)
  • Range setting: 20 Ω
    Resolution: 0.01 Ω
    Accuracy: Hi Current mode: ± (2 % + 4 digits)
  • Range setting: 200 Ω
    Resolution: 0.1 Ω
    Accuracy: No Trip mode: ± (3%)/Hi Current mode: ± (2%)
  • Range setting: 2000 Ω
    Resolution: 1 Ω
    Accuracy: ± 6%

Prospective Earth Fault Current (PEFC) Prospective Short Circuit Current (PSC)

  • Range: 0.0-99.9%
    Resolution: 0.1%
    Accuracy: Consider accuracy of line impedance measurement(s)
  • Note: Voltage drop reading is calculated from line impedance measurement and entered current rating

RCD tests, RCD types tested

  • AC (General, no delay)
  • AC (Time delay)
  • A, F (General, no delay)
  • A, F (Time delay)
  • B, B+ (General, no delay)
  • B, B+ (Time delay)
  • RDC-DD,RCD,A/EV,RCD,B/Mi
  • GFCI

RCD tripping time test (ΔT)

  • x1⁄2, 1:
    10mA
    30mA
    100mA
    300mA
    500mA
    1000mA
    Var
  • x5:
    10mA
    30mA
    100mA
  • Ramp:
    10mA
    30mA
    100mA
    300mA
    500mA
    1000mA
    Var
  • Auto:
    10mA
    30mA
    100mA
  • Mains voltages 50V – 265V ac, 45/66Hz
  • 100mA, 300mA and 500mA: Type B RCDs require main voltage range of 195V to 265V
  • 1000mA: Type AC RCDs only
  • Var: Type A RCDs are limited to 700mA, not available for type B RCDs

RCD Tripping Current (IΔN) Measurement/Ramp Test

  • Current range: 30% of 110% of RCD rated current (1)
    Step size: 10 % of IΔN (2)
    Dwell time Type G: 300 MS/Step
    Dwell time Type S: 500 M/S Step
    Measurement accuracy ±5%
  • (1): Specified trip current ranges (IEC 61008-1):
    30 % to 150 % for Type A IΔ N > 10 mA
    30 % to 210 % for Type A IΔ N = 10 mA
    20%to210%forTypeB
    50 % to 100 % for Type AC
    35%to140%forTypeA(>10mA)
    35 % to 200 % for Type A (≤ 10 mA)
    50 % to 200 % for Type B
  • (2): 5% for Type B

Earth resistance (RE)

  • Range: 200 Ω/2000 Ω
    Resolution: 0.1 Ω/1 Ω
    Frequency:128Hz
    Output Voltage: 25V

Phase sequence indication

  • Icon: Phase Sequence indicator is active
    Range: 185V to 600V
    Display: “1-2-3: or “3-2-1” for incorrect phase

Fluke 1660 Series and 1670 Series Comparison Chart

16621663 FC1664 FC1672 FC1673 FC1674 FC
Full Colour touch screen
Li-ion Battery
USB-C/BLE interface supports charging and data transferUSB-CUSB-C/BLEUSB-C/BLE
Digital rotary dial – supports new feature additions
Form Capture
Project Setup
Field updatable
Bi-directional data
660V maximum voltage, 600V volt operation
Auto pass/fail limits
Onscreen helps
Voltage drop measurement
Insulation monitoring device (IMD) test
Surge Protection Device (SPD) test
Save results from additional Fluke Connect tools
User programmable Auto test sequence
Wiring polarity checker, detects broken PE and N wires
Insulation resistance
Continuity and resistance
Measure motor windings with continuity test (at 10mA)
Loop and line impedance
Prospective Earth Fault Current (PEFC/IK)
Prospective Short-Circuit Current (PSC/IK)
RCD trip time/RCD trip current (ramp test)
Measure trip time and current for RCD type AC, A and F in one test
RCD variable test current
Automatic RCD test sequence
Phase sequence test
Voltage AC, DC and frequencyAC only
Insulation at L-N, L-PE, N-PE inputs250V, 500V, 1000V250V, 500V, 1000V50V, 100V, 250V, 500V, 1000V250V, 500V, 1000V250V, 500V, 1000V50V, 100V, 250V, 500V, 1000V
Continuity at L-N, L-PE, N-PE inputs
EV Test 6mA DC (RCD A/EV, RCD B/Mi, RCD-DD)
Test smooth DC sensitive RCDs (Type B/B+)
Earth resistance
Standard Auto Test Sequence
Insulation PreTest after function
Loop and line impedance – mΩ resolution
Auto pass/fail results
Fluke Connect compatibility
Fluke Cloud Storage
On/Off switchable Auto Start for continuity, RCD and loop test
USB-C/BLE interfaceIR-USBIR-USB/BLEIR-USB/BLEUSB-CUSB-C/BLEUSB-C/BLE
Memory
Z Max memory
Illuminated display

 

Specifications: Fluke FEV300 EV Charging Station Test Adapter Kit: Type 1 & 2 Connectors

General features
Input voltageUp to 250 V (single phase system) / up to 480 V (three phase system), 50/60 Hz, max 10 A
Internal power consumption3 W max.
FEV300-CON-TY2 PlugAC charging mode 3, suitable to IEC 62196-2 type 2 socket outlet or fixed cable with vehicle connector (type 2, 7P three-phase)
FEV300-CON-TY1 PlugAC charging mode 3, suitable to IEC 62196-2 type 1 or SAE J1772 with vehicle connector (type 1, 5P single-phase)
Dimensions (H × W × D)110  × 45  × 220 mm length without connection cable and test cable
Weight (including type 1 or type 2 connection cable)Approx. 1 kg
Safety standardsIEC/EN 61010-1, pollution degree 2
IEC/EN 61010-2-030, CAT II 300 V, protection class II
Ingress protectionIEC 60529: IP54 (housing)
IEC 60529: IP54 (sockets with protection caps in place, connectors in connected condition or with protection caps in place, otherwise IP20)
Operating temperature-20 °C to 40 °C
Storage temperature-20 °C to 50 °C
Operating humidity range10 % to 85 % relative humidity non-condensing
Storage relative humidity0 % to 85 % non-condensing
Operating altitude2000 m max.
Functions
PE Pre-TestVisible indication >50 V AC/DC between PE conductor and touch sensor
PP SimulationOpen, 13 A, 20 A, 32 A, 63 A
CP StatesState A, B, C, D
CP Error state “E”On/off (CP signal short-circuited to PE)
PE Error state “F” (Earth fault)On/off (interruption of PE conductor)
Outputs (for test purpose only)
Measuring terminals L1, L2, L3, N, PEMax. 250/480 V, max. 10 A
CP signal output terminalsApprox. +/-12 V
Caution: In case of wrong wiring or error of the charging station these terminals may be hazardous.
  • What’s Included

    Fluke 1674FC Multifunction Tester

    • Heavy-duty mains cord with single input connector.
    • Remote control probe, hanging strap, and zero adapter.
    • Test leads, probes, and alligator clips.
    • USB-C charger and Li-ion battery.
    • Hard carrying case.

    Fluke FEV300 Type 2 EV Test Simulator Kit

    • FEV300 Test Adapter with Type 2 Plug.
    • Carrying case.
    • Fluke’s 3-Year Warranty.

🚚 Testersmans Shipping Policy

Free Mainland GB Delivery Over £150

We offer free delivery on most mainland Great Britain orders over £150 (ex VAT).
This applies across England, Wales, and most of Scotland, excluding certain remote or offshore postcodes.

If your order total falls just short of £150, or you’re a returning customer, feel free to contact us — we may be able to offer a discount code or delivery workaround.
📞 01945 738112 | ✉️ [email protected]


📦 UK Delivery Options

We work with both Royal Mail and DHL to offer reliable and flexible delivery across the UK:

  • Royal Mail – Best suited for lighter parcels and for customers in remote regions, including the Highlands, Islands, and Northern Ireland.
  • DHL – Ideal for most mainland UK orders, providing fast, tracked delivery and excellent reliability for time-sensitive shipments.

Our checkout system automatically displays the available delivery services for your postcode and order weight, ensuring you always see the most suitable options.

Note: Heavy, bulky, or freight-only orders will be charged separately.
Our website is designed for quick, transactional purchases rather than bulk or palletised orders.
Please contact us in advance for a tailored freight quotation if your order falls into this category.


⏱ Dispatch & Delivery Timing

We aim to dispatch all in-stock orders promptly, but delivery depends on both when you order and which service you select.

  • UK orders: placed by 2:00 PM Monday–Friday are usually dispatched the same day.
  • International orders: placed by 2:00 PM Monday–Thursday are usually dispatched the same day.

Orders placed after these times are processed the next working day. This means delivery may occur the following day or later, depending on the courier and service selected.

Once dispatched, your chosen delivery service determines how quickly your parcel arrives:

  • Standard services We use Royal Mail Tracked 24 or DHL Parcel as our ‘Standard’ services. They are not guaranteed to arrive next working day.
  • Premium services (e.g. Royal Mail Special Delivery or DHL by Noon) offer guaranteed delivery windows.

If your order is time-sensitive, we strongly recommend choosing a guaranteed service or contacting us before ordering to confirm availability.

Please note: For logistical reasons, we may occasionally adjust the delivery method selected at checkout. For example, smaller items may be better suited to letterbox-friendly packaging or may be at greater risk of delay or loss via certain services. We actively monitor courier and postal service disruptions—including strikes and delays—and may modify shipping arrangements to help ensure timely and secure delivery.


📅 Busy Periods & Delays

We always aim to dispatch promptly, but delivery times may be affected by:

  • Seasonal demand (e.g. Christmas, bank holidays, or industry shutdowns)
  • Courier network delays outside our control
  • Supplier lead times or calibration requirements for certain equipment

If your delivery is time-critical, please contact us before ordering so we can confirm stock and courier availability.


🌍 International Shipping

We ship worldwide using UPS Express Saver® and other trusted global courier partners. All international shipments are tracked and generally dispatched Monday to Thursday to ensure smooth customs clearance and transit.

Estimated delivery times:

  • Europe: 1–2 working days
  • North America: 2–3 working days
  • Asia-Pacific & Rest of World: 3–5 working days

Delivery times vary depending on location, customs clearance, and local courier performance.


💰 Taxes, Customs & Import Duties

International customers are responsible for any applicable taxes, customs charges, or import duties.
These are not included in our product or shipping prices.

Your courier will typically provide a secure payment link for any import charges once your parcel reaches customs.
If import fees are refused and the parcel is returned, we will issue a refund minus all incurred shipping and return costs.


📍 Using Your Own Courier

If you would prefer to arrange collection via your own courier (UK or international), please contact us before placing your order to coordinate collection from our Wisbech warehouse.


📝 Important Notes

  • Please ensure your delivery address and contact number are correct at checkout.
  • Undelivered parcels may be returned to us after a short holding period.
  • Redelivery or return fees may apply, even if your order originally qualified for free delivery.
  • By placing an order, you confirm your understanding and acceptance of this policy.

You may also like…